INPUT / OUTPUT UNIT
25
1.拉出锁扣
2.推起模块
2.Push up the module
1.Pull put the lock
Fig 6.7 Dismounting the module
6.4.5.
ID Set
In order to distinguish extensive module in EtherCAT sub-station, each module has a dial switch on the top side, which is
used to set its ID address in the sub-station.
Dial Switch
Fig 6.8 Dial Switch
Setting method: use a normal screwdriver to turn the arrow on the dial switch to a certain number (0~F). ID of each extensive
module in the same sub-station should not repeated.
Info
Set ID in a sequence from left to right or from up to down. For example, if ER-1311 is No.1, the ID of
modules on its right side is No.2, 3, 4… in sequence.
6.4.6.
Wiring
Wire with diameter no less than 0.3mm and without shielding layer is recommended.
One extensive module may connect up to 12 wires. Follow the wiring procedure:
Insert the wire into the connection hole and hold it. Prepare a normal screwdriver to turn the hole.
Turn the normal screwdriver until it cannot be turned any more.
Содержание ERSA-4C
Страница 1: ...ESTUN ERSA 4C Cabinet E 0301EN 01 MAINTENANCE MANUAL...
Страница 2: ...ESTUN ERSA 4C Cabinet MAINTENANCE MANUAL E 0301EN 01...
Страница 45: ...CONNECTION 31 10 COMMUNICATION CONNECTION Fig 10 1 Communication connection between controller and servo motors...
Страница 55: ...Revision Record 41 Revision Record Revision Date Contents 01 2017 11...