![Estun ERSA-4C Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/estun/ersa-4c/ersa-4c_maintenance-manual_2429737036.webp)
INPUT / OUTPUT UNIT
22
Parameters
Description
Power Supply Mode
TBUS ( No external wiring is required.)
TBUS Consumption Current
≤100mA
Networking Mode
Set module address by dial switch
Size (W×H×D)
112mm×113mm×22.5mm
Weight
About 200g
Working Temperature
0
℃
~40
℃
Storage Temperature
﹣
10
℃
~55
℃
Relative Humidity
50
%
~95
%
, no condensation
Relative humidity not less than 95
%
at 0
℃
Relative humidity not less than 50
%
at 40
℃
Guide Rail Installation
35mm standard U type rail, horizontally installed.
Anti-shock and vibration performance
Consistent with EN 60068-2-6/EN 60068-2-27/29
Anti electro-magnetic interference/radiation
performance
Consistent with EN 61000-6-2/EN 61000-6-4
Protection Level
IP20
Certification
CE
Hot Swap
DI signal support hot-swapping.
TBUS does not support hot-swapping.
6.4.
Mounting and Networking of I/O Sub-station
6.4.1.
Mounting Method
Be sure that the extensive module is powered off before installing, dismantling and connecting.
CAUTION
!
Be careful about electric shock and equipment damage!
6.4.2.
Mounting
Fix couplers and extensive modules on the standard T-BUS terminals.
Содержание ERSA-4C
Страница 1: ...ESTUN ERSA 4C Cabinet E 0301EN 01 MAINTENANCE MANUAL...
Страница 2: ...ESTUN ERSA 4C Cabinet MAINTENANCE MANUAL E 0301EN 01...
Страница 45: ...CONNECTION 31 10 COMMUNICATION CONNECTION Fig 10 1 Communication connection between controller and servo motors...
Страница 55: ...Revision Record 41 Revision Record Revision Date Contents 01 2017 11...
Страница 56: ......