6
General
Shower unit duty cycle: 15
minutes on,
60
minutes off.
Exceeding the units duty cycle
The motor is fitted with a thermal cut out device, if temperatures
become too high the device will cut the power to the motor but will
self-reset once temperatures have normalised.
Noise Level
The acoustic noise from the pump motor has been reduced with
integral foam/rubber mountings. The type of wall can affect noise
levels. Solid walls will provide quieter operation. At full flow this unit will
produce in the region of 55 dBA measured from a distance of 1m.
Running in period
For storage reasons the pump motor has a protective film on the
motor contacts. This may produce a burning smell for a period of up to
5 days after installation, this is normal.
Electrical
Power supply
220-240V at 50Hz, fused at 3 Amps, via a double pole fused switch
(not supplied) with a minimum 3mm contact separation in each
contact.
Power Consumption
150 Watts maximum.
Plumbing Connections
Inlet
2 x 15mm Push-fit manifold.
Outlet
1/2” BSP male.
Specifications