background image

1

INSTALLATION & USER GUIDE

These instructions must be left with the user.

THERMOSTATIC MIXER

MIRA MYLINE

Summary of Contents for MYLINE

Page 1: ...1 INSTALLATION USER GUIDE These instructions must be left with the user THERMOSTATIC MIXER MIRA MYLINE ...

Page 2: ...An adjustable maximum temperature stop is provided which limits the temperature to a safe level Inlet filters are fitted to protect the thermostatic mechanism Guarantee For domestic installations Mira Showers guarantee the Mira MyLine against any defect in materials or workmanship for a period of five years from the date of purchase and the shower fittings for one year For terms and conditions ref...

Page 3: ...cial û Healthcare û Patents and Design Registration Patents GB 2 340 210 GB 2 392 223 GB 2 422 886 European 1 672 257 DE FR GB IT NL SE Germany 60 2005 002 339 9 Patent Applications European 07015846 4 US 2006 0124758 A1 US 2010 0123013 A1 US 2010 0219255 A1 Design Registration GB 001240527 0001 ...

Page 4: ...ould be attended whilst showering Particular consideration should be given to the young the elderly the infirm or anyone inexperienced in the correct operation of the controls 6 Rapid Excessive movement of the flow and or temperature control levers may result in momentary unstable blend temperatures 7 Care is required when adjusting flow or temperature Make sure that the temperature has stabilised...

Page 5: ... 2 mm Hexagonal Key q 1 x Thermostatic Mixer supplied fitted to the backplate q 1 x Concealing Plate q 1 x M4 x 12 mm Grubscrew q 1 x Wall Plugs q 1 x Fixing Screw q 1 x Wall Bracket q 1 x Securing Screw q 1 x 360m Showerhead q 1 x Slide Bar q 1 x Shower Hose 1 25 m Chrome supplied with 2x Sealing Washers q 1 x Slidebar Support q 1 x Hose Retaining Ring q 1 x Clamp Bracket Mira MyLine Mixer Mira M...

Page 6: ...erformance For safety and performance reasons it is recommended that the maximum hot water temperature is limited to 65 C Cold Water Range up to 25 C Minimum Recommended Differential between Hot Supply and Outlet Temperature 12 C Thermostatic Shut down For safety and comfort the thermostat will shut off the mixing valve within 2 Seconds if either supply fails achieved only if the blend temperature...

Page 7: ...te requirements correspond to the information given in section Specifications 1 The Mixer must not be installed in an area where it may freeze 2 For stud partitions alternative fixings may be required 3 Isolating valves must be installed close to the Mixer for ease of maintenance 4 Pipework must be rigidly supported and avoid any strain on the connections 5 Pipework dead legs should be kept to a m...

Page 8: ...droom and ceiling clearance to install the integral slidebar 3 Loosen the 2 backplate grubscrews with the 2 mm hexagonal key supplied and pull the mixer and concealing plate from the backplate 4 Unscrew the inlet nuts from the backplate Cold Outlet Hot Concealing Plate Backplate Inlet Nuts 5 Using the backplate as a guide mark the positions of the fixing holes and the pipe centres Important Make s...

Page 9: ...ework is thoroughly flushed through before connection to the mixer Failure to do so may result in product malfunction and will not be covered under the guarantee 10 Fit the olives onto the inlet pipework and tighten the inlet nuts using a suitable spanner Caution Do not overtighten Important Make sure that the inlet filters are fitted in the inlet nuts as illustrated 11 Make sure that the conceali...

Page 10: ... C and that there is sufficient supply 1 Turnonthemixertothemaximumtemperature i e fully clockwise and full flow and allow the temperature to stabilise 2 Test that the temperature of the water from the shower outlet is hot enough If the temperature is too hot or too cold adjust as follows 3 Loosen the securing screw do not remove fully and lift up the temperature lever to disengage from the contro...

Page 11: ...uide mark the position of the bottom fixing hole for the wall bracket Note The distance from the top of the concealing plate to the screw hole on the wall bracket is 720 mm Note Use a spirit level to make sure that the wall bracket is vertical Slidebar Support Clamp Bracket 700 mm Slidebar Hose Retaining Ring 720 mm 720 To Screw Hole Screw Hole Screw Hole Slidebar Support Wall Bracket 5 After mark...

Page 12: ...ll bracket allow for minor adjustment 8 Install the slidebar assembly into the thermostatic mixing valve 9 Position the slidebar support over the wall bracket and secure with the securing screw as indicated 10 Pass it through the hose retaining ring and install the showerhead onto the hose Note Ensure that the sealing washers are installed into the hose 11 Place the showerhead onto the clamp brack...

Page 13: ...werhead then the flow regulator should be fitted Temperature Control Turn the temperature control lever anticlockwise to decrease the temperature and clockwise to the preset maximum temperature Temperature Control Flow Control Off On Height Adjustment The height of the showerhead is easily adjusted by gently moving the clamp bracket either up or down the slide bar until the required height is achi...

Page 14: ...fferent spray actions Rain Cloud Storm and Burst The showerhead features a rotating head to enable differing spray patterns to be achieved turn the showerhead in the direction shown to activate the different spray patterns 4 5 1 2 6 3 7 8 Rain Storm Cloud Burst ...

Page 15: ...Air lock or partial blockage in the pipework Symptom Water leaking from showerhead Cause Rectification Normal for a short period after shut off Check that the pressures are not in excess of the specifications for the product Renew the mixer valve assembly Lubricants Silicone based lubricants must only be used on the rubber seals Caution Oil based or other lubricant types may cause rapid deteriorat...

Page 16: ... showering systems including electric showers Note for showers with a pressure of below 0 15 bar 1 5 metre head it might be necessary to change the Cloud sprayplate assembly for the LC Low Capacity version in order to achieve a suitable spray pattern Caution The LC sprayplate must not be used on electric showers 1 Use a suitable tool to remove the grommets 2 Using the 2 5 mm hexagonal wrench suppl...

Page 17: ...0 153 Inlet Nuts and Olive 1660 155 Temperature Lever Pack Top 1660 157 Flow Lever Pack Bottom 1778 018 Mixer Valve Assembly 1778 019 Shroud Pack Not illustrated 1660 159 Screw Pack 1660 175 Seal Pack 1663 265 Flow Regulator Pack 1660 157 Flow Lever Pack also includes Securing Nut 1778 018 Mixer Valve Assembly 1778 019 Shroud Pack 1778 019 Shroud Pack 1660 155 Temperature Lever Pack ...

Page 18: ...s Identified B 1668 185 Clamp Bracket 1688 200 360m Showerhead 1688 275 Cloud Assembly LC Low Capacity White 1778 020 Hose Retaining Ring 1778 021 Slidebar 1688 200 360mShowerhead 1778 022 Wall Bracket Assembly 1778 020 Hose Retaining Ring 1603 104 Shower Hose includes 2 Washers 1688 185 Clamp Bracket 1688 200 Showerhead A B A B A B 1688 166 1688 160 1688 162 1778 021 Slidebar 1778 022 Wall Bracke...

Page 19: ...ld up Wall Mounted Soap Dish White 1 1540 278 Chrome 1 1540 279 Wall mounted for use anywhere in or outside the showering area Shower Seat White 2 1536 128 White Chrome 2 1536 129 For use in or out of the showering area Folds up when not in use Maximum User Weight 127 kg 20 stone Note Must be installed onto a solid wall Premium Shower Seat White Chrome 2 1731 001 Grey Chrome 2 1731 002 Stylish sli...

Page 20: ... declines check in this manual to see if simple home maintenance is required If you require further assistance call our Customer Services Team Extended Guarantees A selection of protection plans are available that enable you to cover repair bills for the life of your policy excludes Eire Ring 01922 471763 for more details Helpdesk Service Our dedicated Customer Services Team is comprehensively tra...