Страница 1: ...Care Home Smoke Detector User Guide ESUGSC009 Version 1 0 September 2015...

Страница 2: ...bove disclaimers exclusions or limitations may not apply to you By using the information contained herein you agree that the laws of the State of Israel without regard to principles of conflict of law...

Страница 3: ...Installation Locations 9 3 Installation 11 3 1 Testing the SK2 15 4 Operation 16 4 1 Physical Attributes 16 4 2 Features 17 4 3 Indications 17 4 4 Stopping the Alarm 19 5 Maintenance 20 5 1 Replacing...

Страница 4: ...ions with the Care Home Control Panel CP from a remote location Figure 1 Essence Smoke Detector The SK2 peripheral device model identification number is ES700SK2 NOTE The images of batteries included...

Страница 5: ...al life of two years not provided NOTE To comply with the UL certification standards use GP International Ltd batteries 2 2 Location Recommendations As a fire prevention device there are standard loca...

Страница 6: ...72A 72B 72C 72D and 72E for fire alarm requirements in buildings not defined as households 2 2 2 Acceptable Installation Locations For complete coverage smoke alarms should be installed in all rooms...

Страница 7: ...s in a single floor residence with more than one sleep zone Figure 4 Multiple floor Residence Figure 4 above shows an example of locations for installing smoke alarms in a multiple floor residence wit...

Страница 8: ...eiling no closer than 10 cm 4 in from any wall or corner If ceiling mounting is not possible and wall mounting is permitted by the local and state codes mount on a wall 10 15 cm 4 to 6 in from the cei...

Страница 9: ...r choosing an installation location Avoid air streams that have combustion particles Combustion particles are by products of something that is burning A smoke alarm can sense combustion particles in n...

Страница 10: ...vents air conditioners heaters or fans Fresh air vents and drafts can drive smoke away from smoke alarms Avoid dead air spaces near the top of a peaked roof or in the corners formed by ceilings and w...

Страница 11: ...Remove the mounting bracket from the SK2 by rotating the bracket counter clockwise as in 2 Figure 5 below to release the bracket tabs Figure 5 Release the Mounting Bracket Attached to the SK2 Place t...

Страница 12: ...o the ceiling or wall using the screws 7 WARNING Do not connect the SK2 to any other alarm or auxiliary device Connecting anything else to the SK2 prevents the proper operation of the alarm Press the...

Страница 13: ...cessful the CP beeps and the ring around the CP EMERGENCY button blinks Blue three times If the pairing process is not successful the CP beeps and the ring lights up Red for two seconds If the periphe...

Страница 14: ...Installation 14 Care Home Smoke Detector User Guide Figure 8 Align Slots Turn the SK2 clockwise on the bracket until you hear a click 13 Figure 9 Turn SK2 Clockwise to Install...

Страница 15: ...ssful perform the following procedure Pull the smoke alarm downward to make sure it is securely attached to the mounting bracket 1 WARNING To prevent injury the SK2 must be securely attached to the ce...

Страница 16: ...The alarm is real There is smoke A possible fire The alarm is false If the alarm is triggered by smoke from a non serious event such as smoke from cooking open a 2 window and fan the air to remove the...

Страница 17: ...ows Power Green Fault Yellow Alarm Red 4 2 Features The following are the characteristics and features of the SK2 RF communications with the CP allows for SMS and e mail notifications The RF connectiv...

Страница 18: ...alarm of 3 beeps a pause and then another 3 beeps Push the TEST MUTE button to suspend the alarm for five minutes When suspended the SK2 re assesses the smoke level If the smoke has not dissipated the...

Страница 19: ...es smoke To dissipate the smoke do the following Open a window s in the room where the SK2 is installed Fan the air around the smoke alarm If the alarm persists clean the SK2 as described in section 5...

Страница 20: ...ve the SK2 from the mounting base as illustrated in Figure 12 below turn the SK2 counter 1 clockwise until you hear a click The SK2 is freed from the bracket Figure 12 Open the Mounted SK2 for Mainten...

Страница 21: ...ice specifications listed in Table 3 on page 25 The SK2 may not operate properly with any other kind of battery 5 2 Testing the SK2 Test the SK2 once a month or at any time the device appears not to b...

Страница 22: ...ood working condition test the SK2 once a month and clean it once a year To clean the SK2 perform the following procedure To remove the SK2 from the mounting base as illustrated in Figure 12 on page 2...

Страница 23: ...n the SK2 slots with the bracket tabs as illustrated in Figure 8 on page 14 and insert the 5 bracket tabs into the SK2 slots Turn the SK2 clockwise on the bracket until you hear a click 6 Test the SK2...

Страница 24: ...e is computed according to ESI s standard usage parameters System Compatibility Care Home Wireless Bi directional End to End bi directional ESI protocol Modulation and Frequency FSK modulation 868 3 M...

Страница 25: ...ashes rapidly 8 times Test fail The combination of the alarm and the LED indicate the specific problem Security and Safety Tamper Feature Loud continuous sound is triggered and the LED flashes continu...

Страница 26: ...me or sparks Keep electrical appliances in good condition Do not overload electrical circuits Keep stoves fireplaces chimneys and barbecue grills grease free Make sure they are properly installed and...

Страница 27: ...not stop to collect anything or to get dressed Feel the doors to see if they are hot If they are not hot open them carefully Do not open a door that is hot Use an alternate escape route Stay close to...

Страница 28: ...waken individuals who are sound sleepers If the sound of the smoke alarm does not easily wake up children or other family members or if there are infants or family members with mobility limitations ma...

Страница 29: ...er side script engine for dynamically generated web pages CP An Essence Term Control Panel DIY Do It Yourself DMZ Demilitarized Zone In computer security a DMZ is a physical or logical sub network tha...

Страница 30: ...radio signals to transfer data from a tag attached to an object for automatic identification RIA Rich Internet Application Web application with many characteristics of desktop application software Ty...

Страница 31: ...t of methods and a network protocol to allow an end host to discover its public IP address if it is located behind a NAT STUN is used to permit NAT traversal for applications of real time voice video...

Страница 32: ...provided deployed or enforced by any functionality including without limitation digital rights management functionality contained in the Application 3 use the Application to access copy transfer or re...

Страница 33: ...s and it is your responsibility to secure access to the system with pass codes and lock outs c The Application is designed to utilize your enabled cellular Device to access the System The Device will...

Страница 34: ...esent links in a format that enables us to keep track of whether these links have been followed Third Party Sites This Privacy Policy applies only to the Application functionality on the System or a D...

Страница 35: ...are solely responsible for providing communication pathways for the System to communicate upon activation Notwithstanding the forgoing Company shall not be responsible for loss of System connectivity...

Страница 36: ...f service or down time of remote access caused by loss of Internet service or cellular used by you for the System and the access of the System You acknowledge that the System can be non functional or...

Страница 37: ...y who enters your home and if said third party is a child or is under a legal guardian s responsibility their legal guardian that they may be monitored and or photographed and or recorded without thei...

Отзывы: