Esse O-106 Скачать руководство пользователя страница 2

3

General Information

Page 3

Technical Data

Page 3

General Location

Page 4

Electrical Supply

Page 4

Oil Supply

Page 4

Ventilation

Page 4

Chimney/Flueing Arrangement

Page 4

Water Systems & Wiring Diagrams

Page 5

Installation

Page 6

Door Hinge Adjustments

Page 6

Commissioning

Page 7

Comissioning the Programmer -

O-60, O-80 & O-106 models

Page 10

Comissioning the Programmer -

OC Model

Page 11

Fault Finding Chart

Page 17

Commissioning Record

Page 18

Service Record

Page 19

Replacement Parts

Page 20

The installation of the cooker, the chimney, hearth and walls adjacent to the cooker must conform to local

or national regulations currently in force. In the United Kingdom, the appropriate sections of the Building

Regulations must be conformed to.

O-106

29.3 (Output)

1.0

7.2

3.42

7.5

11.8

0-1

(100,000)

80°ES

105

8.5

10.8

O-80

23.44 (Output)

0.75

7.6

2.63

2

11.4

0-1

(80,000)

80°ES

110

3

10.4

O-60

17.54 (Output)

0.6

7.0

1.97

2

11.1

0-1

(60,000)

80°ES

100

1

10.1

COOKER BURNER

OVERALL AIR SUPPLY & FUEL CONSUMPTION

TECHNICAL DATA

O-106, O-80,

10.55 (Input)

0.3

6.0

0.99

MIN +

6.0

0-1

O-60, OC

36,000 Btu/h

80° A or H

87

1 notch

4.5

O-106

170

4.41

O-80

130

3.62

O-60

100

2.96

MODEL

AIR SUPPLY MIN

TOTAL FUEL CONSUMP

CM

2

l/h*

MODEL

OUTPUT/INPUT

Nozzle

Pressure

Fuel

Air

C02

Soot No

kW

Size

bar

Consump.

Setting

%

(Btu/h)

Type

(p.s.i.)

l/h*

Approx

BOILER BURNER

GENERAL INFORMATION

CONTENTS

HEALTH & SAFETY AT WORK ACT 1974

(AND AMENDMENTS)

The installer has a responsibility under this Act, to provide

for the safety of person(s) carrying out the installation.

Attention is drawn to the following:-

1) The appliance is heavy and requires care in handling.

Lifting off the pallet and positioning may be carried out

using the Lifting Jack* available from ESSE dealers.

There may also be sharp edges on certain

components.

2) Fire cement is caustic and hands must be washed

thoroughly after use.

Although this appliance does not contain asbestos

products, it is possible that asbestos may be disturbed in

existing installations and every precaution must be taken.

*Patent applied for.

Important OC InstalLation INFOrmation:

OC

(cooking

only)

models

should

be

installed using the cooker burner instructions
only. OC models do not have a boiler and
therefore all boiler instuctions are not
required and can be ignored.

* Constant Running

† This pressure must not be exceeded

Содержание O-106

Страница 1: ...lame Tube BFB 01 002 002 01 01 1001 D 0 60 BURNER Nozzle 0 6 x 80ES 2021 254 Flame Tube BFB 01 104 01 01 1010 2 COOKER BURNER Nozzle Danfoss 0 3 x 80 H or Delavan 02 02 1150 0 3 80 A Flame Tube BFB 01...

Страница 2: ...0 1 O 60 OC 36 000 Btu h 80 A or H 87 1 notch 4 5 O 106 170 4 41 O 80 130 3 62 O 60 100 2 96 MODEL AIR SUPPLY MIN TOTAL FUEL CONSUMP CM 2 l h MODEL OUTPUT INPUT Nozzle Pressure Fuel Air C02 Soot No kW...

Страница 3: ...e fitted to the programmer Commission the programmer as described in figs 3a 3b Typical systems are shown in Figs 4 5 5A 6 6A The water system and the electrical wiring system used must be in accordan...

Страница 4: ...em can allow the boiler and pump to operate on bypass only the bypass must be placed at least 1 5m 5 3 away from the boiler Inhibitor Attention is drawn to the current issue of BS5449 and BS 7593 on t...

Страница 5: ...is firing check and if necessary adjust oil pressure see Technical Data Carry out combustion checks by inserting probe into sampling point provided at the flue box Fig 8 The air setting is pre set at...

Страница 6: ...CentaurPlus controls are fitted with battery reserve which maintains programmed times in the event of a mains power failure Battery Reserve The battery must be commissioned prior to fitting the contr...

Страница 7: ...L Boiler stat Boiler burner Cooker programmer Cylinder stat L641A or equivalent DHWS Cylinder primary motorised valve 28mm V4043H or equivalent Heating circuit motorised valve V4043H or equivalent Roo...

Страница 8: ...1 L N E HORSTMANN C17 Model OC COOKER ONLY Fig 6a Boiler stat Boiler burner Cooker programmer Cylinder stat L641A or equivalent DHWS Cylinder primary motorised valve 28mm V4043H or equivalent Heating...

Страница 9: ...nce overheat device has operated Control relay or photo cell defective Burner fails to start Lamp not lit Oil not being delivered Excess flue draught is preventing flame establishment No spark Burner...

Страница 10: ...Tel No Fax No OFTEC Reg No Engineers Name Date Address Tel No Fax No OFTEC Reg No Engineers Name Date Address Tel No Fax No OFTEC Reg No 18 Engineers Name Date Address Tel No Fax No OFTEC Reg No Engin...

Отзывы: