MINIMUM OPERATIONS TO VERIFY PROPER INSTALLATION
Page 17
MINIMUM OPERATIONS TO VERIFY
PROPER INSTALLATION
1. PROGRAMMING
Access to programming: lift the local telephone handset and dial
.
The programming activated message will be heard.
Program a telephone number for the emergency-call alarm:
dial
<telephone number>
.
Record the identification message of the specific elevator, which is
meant to contain all necessary information concerning the elevator
location: dial
and, after the “Correct” message, pronounce
the message and hang up.
To listen again to the previous message: lift the handset and dial
.
Make an external call to check the PSTN line or the universal GSM
gateway is properly working: dial
and digit the telephone number to
make a test call.
2. TESTING THE ALARM PROCEDURE
Press the emergency call button for more than 3 seconds (factory
value).
The alarm starts.
3. ANSWERING THE ALARM
Note: the activation mode of the communication with the trapped
person can be configured with the “Handsfree connection
mode during an alarm” programming (code 78).
-1
st
mode: automatic handsfree connection after the messages
(factory default)
Answer by the called party.
The handsfree mode will be activated after the voice messages.
Speak with the trapped person.
-2
nd
mode: handsfree connection by “Handsfree activation” code
Answer by the called party.
Содержание HELPY 2W-Q
Страница 14: ...Page 14 WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAM WITH 2W SPEAKER UNITS ON CAR TOP AND IN THE PIT...
Страница 15: ...WIRING DIAGRAMS Page 15 WIRING DIAGRAM WITH PASSIVE SPEAKER UNITS...
Страница 16: ...Page 16 WIRING DIAGRAMS WIRING DIAGRAM WITH LANDING FLOORS...
Страница 34: ...Page 34 NOTE NOTE...
Страница 35: ...NOTE Page 35...