TERMINAL BLOCKS
TERMINAL BLOCKS
+
Power supply input 12 Vdc or 24 Vdc
-
Negative
AI
Given alarm indicator light (12 Vdc)
AR
Received alarm indicator light (12 Vdc)
+12
12 Vdc output (max. 100 mA)
C
Common terminal
(1)
for inputs AL1 and IN1
-
Negative
AL1
Alarm input
(2)
1 (built-in pushbutton)
AL2
Alarm input
(3)
2 / Auxiliary input
(3)
/ Reset input
(3)
IN1
Filter input
(2)
/ Reset input
(3)
ALT2
Output for connecting loudspeaker of passive speaker unit
MIC2
Input for microphone of passive speaker unit or single microphone
MIC3
Input for microphone of passive speaker unit or single microphone
-
Negative
TEL
Local telephone
RL1
Relay
(4)
Ground terminal for telephone line
LTI
PSTN-line or universal GSM gateway input
LTI
PSTN-line or universal GSM gateway input
BUS+
Bus for connecting 2W
speaker units
BUS
-
Bus for connecting 2W speaker units
TX
TX for serial connection to elevator CPU (RS-232)
RX
RX for serial connection to elevator CPU (RS-232)
(1)
:
can be connected to a block
–
, to the block +12 or to an external reference
(2)
:
allows to connect voltage free contact pushbuttons (NO or NC) or powered pushbuttons
(3)
:
allows to connect voltage free contact (NO or NC)
(4)
:
free contact NO
Double contact built-in pushbutton
C
Common
NO
Normally open
NC
Normally closed
Содержание HELPY 2W-Q
Страница 14: ...Page 14 WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAM WITH 2W SPEAKER UNITS ON CAR TOP AND IN THE PIT...
Страница 15: ...WIRING DIAGRAMS Page 15 WIRING DIAGRAM WITH PASSIVE SPEAKER UNITS...
Страница 16: ...Page 16 WIRING DIAGRAMS WIRING DIAGRAM WITH LANDING FLOORS...
Страница 34: ...Page 34 NOTE NOTE...
Страница 35: ...NOTE Page 35...