SMS / E-MAILS THROUGH DB-9
4G.VoLTE CAN gateways allow devices connected to the DB-9
connector (in standard RS-232, RS-485 or CAN-bus) to send or receive
SMS and to send e-mails.
DB-9 PROGRAMMING
COMMUNICATION
STANDARD
**12*X#
X: option, from 0 to 3
0= communication disabled
1=
RS-232
2= RS-485
3= CAN-bus
(for CAN-bus communication please refer to
corresponding documentation)
COMMUNICATION
PARAMETERS
(this programming
can be effectuated
only after the
communication
standard
programming)
**57*XYWZ#
X: bits per second, parameter from 1 to 9
1=
RS-232/485: 115200 / CAN-bus: 1M
2= RS-232/485: 57600 / CAN-bus: 500k
3= RS-232/485: 38400 / CAN-bus: 250k
4= RS-232/485: 19200 / CAN-bus: 125k
5= RS-232/485: 9600 / CAN-bus: 64k
6= RS-232/485: 4800 / CAN-bus: 50k
7= RS-232/485: 2400 / CAN-bus: 20k
8= RS-232/485: 1200 / CAN-bus: 10k
9= RS-232/485: 600 / CAN-bus: 5k
Y: data bits, parameter from 0 to 1
0=
8
1= 7
W: stop bits, parameter from 0 to 1
0=
1
1= 2
Z: parity, parameter from 0 to 2
0=
none
1= even
2= odd
Note: if data bits = 7 is not possible to set parity = none
Note:
for CAN-bus communication please enter
**57* X(bits per second) 000#