Page 23
If the battery check is enabled, the gateway detects the presence of the
battery. If the battery is absent or in case of disconnection, a notification
SMS is sent to the programmed number with the following text message:
“
Dead battery
”.
(3)
External power failure control
If the control on external power failure is enabled, the gateway constantly
controls the external power supply (230 Vac or 12 Vdc). If the external
power failure lasts longer than the preset time interval, a notification SMS
is sent with the following text message: “
External power failure
”.
If the external power supply is restored for a time interval equal to the
preset threshold a new SMS will be sent with the following text message:
“
External power restored
”.
(4)
Relay-based notification of external
power failure and/or mobile network loss
If the relay-based notification of mobile network loss is enabled, when the
mobile network is restored, a notification SMS is sent with the following
text message: “
Mobile network restored
”.
(5)
Periodic test
If the periodic test is enabled, the gateway sends, with programmable
frequency, an SMS or a CLI call to the set number.
The SMS is sent with the following text message: “
Periodical test
message
”.
Note:
the CLI call is a call that does not need to be
answered.
Note: for the correct operation of the Periodic test, to
program the internal clock of the device is required
(see the programming “CLIP setting”).