APPENDIX K - Esprit TECHNICAL SPECIFICATION

ASYNCHRONOUS DATA CHANNELS

Interface:

V.24/V.28 (DCE)

Capacity:

8 or 16 Channels

Data Rates:

0 to 115200bps (0 to38400bps for 8 channel)

Data Format:

5,6,7,8 bit data

Stop Bits:

1, 1½, or 2 stop bits

Data Parity:

EVEN, ODD or NONE

Data Flow Control:

In Band: XON/XOFF(DC1/DC3).
Out Of Band: CTS (Data to Mux), DTR (Data from Mux)

Diagnostics:

Local and Remote Loopbacks. 'Quick Brown Fox' test messages.  Echo
Mode

Flags:

RTS may be set ON, OFF or to follow DSR from the Remote mux

COMPOSITE LINK

Interface:

V.11 , V.35 , V.24 (all DTE)

Data Rates:

Up to 256Kbps (64K for V.24 or 8 channel version), Clock Source 
Internal or External

Transmission Modes:

HDLC

SUPERVISOR PORT

Interface:

V.24/V.28 (DCE)

Data Rate:

9600bps asynchronous

Data Format:

8 bits, no parity, 1 stop bit

Supported Terminals:

VT52, VT100, ADDSVP, ADM3A, H1500, N8009, TVI920

GENERAL

Front Panel Indicators:

Carrier, Loop, Error.

Dimensions:

434mm x 274mm x 61mm

Weight:

2.6Kg

Environment:

Operating 0-40

C, 0-90% humidity non-condensing

Содержание Statmux

Страница 1: ......

Страница 2: ...en fitted in accordance with the installation instructions against the following directives standards Low Voltage Directive 73 23 EEC and amendment 93 68 EEC EN60950 1992 Safety Electromagnetic Compat...

Страница 3: ...Up display layout 8 2 7 General Keyboard Conventions 8 2 8 Composite confiuration 2 9 Statmux channel configuration 10 2 10 Copying another channel s set up 10 2 11 Modem Configuration Options 12 3 I...

Страница 4: ...ments 24 D Rear Panel Layout 26 E Supervisor Port Pinout V 24 25 Way D Type DCE 27 F Composite Link Interface Pinouts DTE 28 G V 24 V 28 Data Channel Pinout 8 Way RJ45 Type DCE 29 H Composite Link Net...

Страница 5: ...y be used with Dial up Modems and Leased lines such as KiloStream up to 256 Kbps in the case of the 16 channel unit or 64Kbps for the 8 channel The unit is easily configured from either end of the lin...

Страница 6: ...ports synchronous link rates of up to 256Kbps 64Kbps for the 8 channel unit either dial up or leased line for connection to Modems or digital services such as BT KiloStream The sixteen channel unit wi...

Страница 7: ...y NONE Flow Control XOFF RTS ON Mode NORMAL 2 3 Changing the Configuration The Esprit may be configured using an asynchronous terminal A laptop PC running an asynchronous terminal emulation program su...

Страница 8: ...ONE Flow Control XOFF XOFF XOFF XOFF XOFF XOFF XOFF XOFF RTS ON ON ON ON ON ON ON ON Mode NORMAL NORMAL NORMAL NORMAL NORMAL NORMAL NORMAL NORMAL More More Cursor Keys to move CTRL U to save ESC to ab...

Страница 9: ...onventions Only a few keys are required to configure the Esprit multiplexer and are summarised as follows Right arrow Moves the cursor to the next field to the right Left arrow Moves the cursor to the...

Страница 10: ...e local and remote end as necessary and held in Non Volatile Memory NVRAM 2 7 4 Abandoning Changes Pressing ESC at any point before a configuration is updated will cause the message Abandon Changes y...

Страница 11: ...e on the right hand area of the screen next to Channels 1 16 Channels 1 8 and pressing ENTER or RETURN The display shows parameters for eight data channels CH1 to CH8 or CH9 to CH16 The alternative 8...

Страница 12: ...top Bits 1 1 5 or 2 Number of stop bits per asynchronous character Parity EVEN ODD or NONE Asynchronous data parity Flow Control XOFF XOFF use XON XOFF soft CTS CTS Uses DTR input to NONE No Flow cont...

Страница 13: ...ick Brown Fox message via link to remote port LOOP R Set this at remote site to loop back data to local via link 2 11 Modem Configuration Options The screen below shows the Modem Configuration options...

Страница 14: ...1 3 Page 13 of 36 30 Seconds 1 Minute Time before call is 2 Minutes 5 Minutes automatically dropped if no 15 Minutes 30 Minutes further data flow detected 60 Minutes Status No Options Gives the curren...

Страница 15: ...Temperature 0 to 40 degrees centigrade Humidity 0 to 90 non condensing Air Pressure 86 to 106 kPa 3 3 Mechanical Construction The Esprit is housed in a 1 5U tall 19 enclosure An optional rack mount ki...

Страница 16: ...f X21 V11 V35 and V24 The composite port appears on the back panel as a 15 way D type connector the pin out for each interface standard being shown in Appendix F Correct cables for Network connection...

Страница 17: ...NTERNAL 64K set on INTERNAL V 11 V 24 V 35 Present Shows whether the link Lost is successfully connected Mode NORMAL Normal RUN Mode LLOOP Loops all transmitted data to the receiver Configuration LOCA...

Страница 18: ...lash Call established searching for synchronisation Steady Green Call in progress passing data OK LOOP Not illuminated Normal un looped mode Green Some Channels looped or in QBF test modes ERROR Red R...

Страница 19: ...o under off line conditions as many have very large buffers which can give a misleading indication that flow control is working when it is in fact not ever requested by the printer 4 3 Back to Back Te...

Страница 20: ...it requests received Throughput Data throughput in bytes second Frames Received Number of frames that have been received across the composite link Frames Errors Number of frames that have errored whil...

Страница 21: ...network WARNING INSTALLATION OF EQUIPMENT Installation of this equipment must only be performed by suitably trained service personnel WARNING CONNECTION OF OTHER EQUIPMENT This equipment allows connec...

Страница 22: ...Netzen erlischt Warnung Installation des Ger tes Die Installation des Ger tes darf nur von entsprechend ausgebildetem und autorisiertem Personal durchgef hrt werden Warnung Anschlu von anderen Ger te...

Страница 23: ...uniquement par des personnels convenablement form s ce type de mat riel Mise en garde Connexion d autres quipements Des quipement compl mentaires pourrant tre connect s aux ports de cet quipement la...

Страница 24: ...ble is available from your dealer using the specified part number V 35 Throughout Europe Pan European to I CTR2 at data rates up to and including 256Kbps when the composite interface is configured to...

Страница 25: ...and 25 way D Type ports The cables must have the foil or braid screen connected effectively to the metal headshell to ensure continued compliance The following headshells are among those which have be...

Страница 26: ...1 3 Mains Connection The mains connection is internally filtered and requires no special consideration C 2 To Ensure that adequate immunity is achieved It is in the user s interest to ensure continued...

Страница 27: ...3 Page 26 of 36 APPENDIX D Rear Panel Layout The layout of all ports on the rear panel of a 16 channel Esprit multiplexer is shown in the diagram below the 8 channel version doesn t have ports 9 16 No...

Страница 28: ...7 Common 8 DCD 20 DTR 9600bps Operation The multiplexer requires connections to TxD RxD and Common only The output signals CTS DSR and DCD are provided for the terminal if required Cable for connectio...

Страница 29: ...OTECTIVE GROUND 8 G COMMON COMMON Common Return 2 T A TXDa TXD Generator 9 T B TXDb Generator 3 C A DTR DTR Generator 10 C B Generator 4 R A RXDa RXD Load 11 R B RXDb Load 5 I A DCD DCD Load 12 I B Lo...

Страница 30: ...IX G V 24 Data Channel Pinout V 24 Data Channels connectors 1 16 8 Way RJ45 Type Configured DCE DATA CHANNEL CONNECTIONS Description DCE RJ45 Type Protective Ground TxD 6 Load RxD 5 Generator RTS 8 Lo...

Страница 31: ...Generator 10 10 C B Generator 4 4 R A Load 11 11 R B Load 5 5 I A Load 12 12 I B Load 6 6 S A Load 13 13 S B Load Notes 1 Pin 14 on Mux not Connected 2 V11 Male for connection to NTU must have M3 Scre...

Страница 32: ...A SHIELD 8 B COMMON Common Return 2 P TXDa Generator 9 S TXDb Generator 15 C RTS Generator 3 H DTR Generator 4 R RXDa Load 11 T RXDb Load 5 F DCD Load 6 V RXCa Load 13 X RXCb Load 7 Y TXCa Load 14 AA...

Страница 33: ...onnector Connector UNC 4 40 Screws UNC 4 40 Screws Normal Use 1 1 SHIELD 8 7 COMMON Common Return 2 2 TXD Generator 15 4 RTS Generator 3 20 DTR Generator 4 3 RXD Load 5 8 DCD Load 6 17 RXC Load 7 15 T...

Страница 34: ...t Cables Back to Back cable spec fo X 21 V 11 V 24 and V 35 Signal Name 15 way D male Mux A 15 way D male Mux B Common 8 8 TxDa RxDa 2 4 TxDb RxDb 9 11 RxDa TxDa 4 2 RxDb TxDb 11 9 Clocka Xclocka 6 7...

Страница 35: ...ator modem up as follows AT F0 Set Defaults AT M2 Set SYNCHRONOUS DTR dialling AT D2 DTR required for modem to go online AT S1 DSR Responds to remote modem AT Z0 tel No Set telephone number AT W Save...

Страница 36: ...Local and Remote Loopbacks Quick Brown Fox test messages Echo Mode Flags RTS may be set ON OFF or to follow DSR from the Remote mux COMPOSITE LINK Interface V 11 V 35 V 24 all DTE Data Rates Up to 25...

Страница 37: ...Esprit Statmux User Manual December 1997 Issue 1 3 Page 36 of 36 Power Requirements 100 240V AC 50 60Hz...

Отзывы: