background image

- 10 - 

 

 

Accepting changes. 

Return to the general screen from display of parameters. 

 

Pressure:        2.0bar

Menu

View

 

Backlight

Backlight

Backlight

Backlight    
The screen is backlit display for better reading. 
To save power, the backlight turns off in 60 seconds without pressing any keys. 
To activate the backlight, press OK

OK

OK

OK. 

Without backlight does not work any other key. 

 

5.3)

5.3)

5.3)

5.3) Description of the menus.

 Description of the menus.

 Description of the menus.

 Description of the menus.    

START SCREENS

START SCREENS

START SCREENS

START SCREENS    

 

Introduction screen

Introduction screen

Introduction screen

Introduction screen    
Displayed during a few seconds when connecting the equipment. 

Indicates: model, software version and pressure sensor configuration. 

 

Start screen

Start screen

Start screen

Start screen    
The pump is not activated. 
To start the pump manually, press 

 (Man) 

For automatic operation, press

 

 (Auto) 

To configure parameters, press 

 (Config) 

MAIN SCREEN

MAIN SCREEN

MAIN SCREEN

MAIN SCREEN    

 

It shows the system pressure. The pump will run automatically, as needed. 
To display parameters, press 

 (View) 

To return to the start screen, press 

 (Menu) 

 
MANUAL OPERATION

MANUAL OPERATION

MANUAL OPERATION

MANUAL OPERATION    

 

It shows the system pressure and Speedrive output frequency. 
Press

 

 ON, to activate the pump. Start-up is always performed at 15Hz. 

Press

 OFF, to stop the pump. 

Press

 or 

, to adjust the frequency. 

Press O

O

O

OK

K

K

K to exit the screen. 

 

CONFIGURATION

CONFIGURATION

CONFIGURATION

CONFIGURATION    

 

Screen descriptions: 

Top : parameter being configured. 

Lower left : current value of the parameter. 

Lower right, "flashing": new value being configured. Press OK

OK

OK

OK to confirm. 

 

LANGUAGE

LANGUAGE

LANGUAGE

LANGUAGE    
Select the desired language.    

 

MOTOR FREQUENCY

MOTOR FREQUENCY

MOTOR FREQUENCY

MOTOR FREQUENCY    
Configuration of the nominal frequency of the motor, 50Hz or 60Hz. 

Check the motor's nameplate. 
Note: This screen only appears in the initial preset or retrieving the factory 
settings. 

 

MAXIMUM PUMP HEIGHT

MAXIMUM PUMP HEIGHT

MAXIMUM PUMP HEIGHT

MAXIMUM PUMP HEIGHT    
Setting the maximum pressure the pump can provide. 

Check the pump’s nameplate. 
Note: This screen only appears in the initial preset or retrieving the factory settings    

Содержание SPEEDRIVE

Страница 1: ...SPEEDRIVE INSTRUCTIONS MANUAL INSTRUCTIONS MANUAL INSTRUCTIONS MANUAL INSTRUCTIONS MANUAL EN EN EN EN...

Страница 2: ...he pump or the installation TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS 1 GENERAL INFORMATION 3 2 TECHNICAL SPECIFICATIONS 3 2 1 Models 3 2 2 Dimensions 3 2 3 Features 3 3...

Страница 3: ...his Manual can lead to motor overloads diminishment in technical characteristics reduction of the unit s working life and all types of subsequent results for which we decline any responsibility 2 TECH...

Страница 4: ...es are primed completely 3 2 Elect 3 2 Elect 3 2 Elect 3 2 Electrical connection to the motor rical connection to the motor rical connection to the motor rical connection to the motor 3 2 1 Speedrive...

Страница 5: ...inverter set DANGER Risk of electrocution Never open the Speedrive cover before disconnecting the power supply during at least 5 minutes least 5 minutes least 5 minutes least 5 minutes Figure 2 Figure...

Страница 6: ...e Three Three Three Phase Version Phase Version Phase Version Phase Version Prepare the motor wires with ferrites connect the grounding wire 2 Connect the motor wires to the provided socket 3 Single S...

Страница 7: ...size Motor size Motor size Motor size Leakage current Leakage current Leakage current Leakage current 0 75 to 3 kW 3 5 mA 4 to 5 5 kW 5 mA The electrical installation should have a multiple separatio...

Страница 8: ...used 5 Auxiliary transducer input Not used 6 Only in single phase versions 230 V potential output 2A maximum external display or acoustic operation for alarm signals 7 Micro switches used to configur...

Страница 9: ...equipped pumps point for equipped pumps Do not need any further adjustment Do not need any further adjustment Do not need any further adjustment Do not need any further adjustment Speedrive module pur...

Страница 10: ...ressure The pump will run automatically as needed To display parameters press View To return to the start screen press Menu MANUAL OPERATION MANUAL OPERATION MANUAL OPERATION MANUAL OPERATION It shows...

Страница 11: ...by experts ADDITIONAL PARAMETERS SETTING ADDITIONAL PARAMETERS SETTING ADDITIONAL PARAMETERS SETTING ADDITIONAL PARAMETERS SETTING FINE ADJUSTMENTS FINE ADJUSTMENTS FINE ADJUSTMENTS FINE ADJUSTMENTS T...

Страница 12: ...does not have to be determined since the circuit communications system detects its number DELAY ON DELAY ON DELAY ON DELAY ON Delay time between the activation of auxiliary pumps Avoid continuous star...

Страница 13: ...T PROPORTIONAL CONSTANT START PROPORTIONAL CONSTANT START PROPORTIONAL CONSTANT START PROPORTIONAL CONSTANT Allows the variation of the unit s proportional constant upon start up STAR INTEGRAL CONSTAN...

Страница 14: ...o the main screen 2 1 From any screen tap OK to return to the main screen 2 1 From any screen tap OK to return to the main screen 2 1 From any screen tap OK to return to the main screen 2 1 OVERCURREN...

Страница 15: ...m will stop when a short circuit is detected in the motor The reset is automatic If the error is not solved 4 new attempts are performed If the error is still present after the fourth attempt the syst...

Страница 16: ...rious Espa solutions for a multiple pump booster set control a Booster set with On Off auxiliary pumps equipped with ELV box b Booster set with inverter regulated auxiliary pumps equipped with Speedri...

Страница 17: ...rrent of the auxiliary pumps according to his motor s data plate plus 10 plus 10 plus 10 plus 10 All auxiliary pump motors should be of the same power CHANGE FREQUENCY CHANGE FREQUENCY CHANGE FREQUENC...

Страница 18: ...is done as described in this manual The connection of the pressure transducer must be made solely on the Master Speedrive A 2 wire twisted and shielded cable 0 5mm2 section must make the communication...

Страница 19: ...menu as follows MOTOR FREQUENCY MOTOR FREQUENCY MOTOR FREQUENCY MOTOR FREQUENCY Configuration of the nominal frequency of the motor 50Hz or 60Hz Check the motor s nameplate Note This screen only appea...

Страница 20: ...ELECTROMAGNETIC COMPATIBILITY Speedrive M1 and M2 are in compliance with directive 2004 108 CE electromagnetic compatibility for industrial environment For residential environment it will require the...

Страница 21: ...21 10 MENU DIAGRAM 10 MENU DIAGRAM 10 MENU DIAGRAM 10 MENU DIAGRAM...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...Cod 155854 Cod 155854 Cod 155854 Cod 155854 11 11 11 11 2010 05 2010 05 2010 05 2010 05 ESPA 2025 S L C Mieres s n 17820 BANYOLES GIRONA SPAIN www espa com...

Отзывы: