The mass flow meter can be configured in function of the following operating parameters:
Type of mass flow meter:
Modbus
–
Krohne, MicroMotion, Hauser JP10, JP11 on the left
Impulsive
–
Rheonik, MicroMotion, Hauser JP10, JP11 on the right
Rating:
5V
200mA (MAX) insert the Jumper in VP5 position
12V
100mA (MAX) insert the Jumper in VP12 position
mutual exclusive
24V
50mA (MAX) insert the Jumper in VP24 position
Exit channels (in case of an impulsive meter):
Active low channel
JP4 jumper opened
Active high channel
JP4 jumper closed
The connection terminals of the mass flow meter must be used exclusively to
connect the mass flow meter itself. It is not possible to use the power supply
terminal for other purposes than the foreseen.