EW055.600D
D
4L
6
th
June 2018
31
43
EsiWelma
®
s.r.l.
JP4
Open = Pulser ChA active Hight
Closed = Pulser ChA active Low
5. HARDWARE PERSONALIZATION
On the CPU 3 selectors (JP) are available. They are placed in the case protected by the
metrical seal and allow to modify the functionality of the computing head as follows::
JP1
Delivered quantity expressed in Kg or in Smc
Open
Kg
Close
Smc
JP2
Enables and performs Set-up operations
Open
normal
delivering
Close
set-up
enabled
JP3
Forces the head to use the parameters in congruence with the Euro,
unbounded from the current set-up:
Open
utilizes
Set-up values
Close
utilizes values in congruence to
Euro
Photo 4: Set-up jumper on CPU
VP24 24V Pulser supply
VP12 12V Pulser supply
VP5 5V Pulser supply
JP10 - JP11
Rigth
= Impulsive Meter
Left
= Modbus Meter
JP2
Open
→
Delivery
Closed
→
Setup
JP3
Open
→
Valuta
Closed
→
Euro
JP1
Open
→
Kg
Closed
→