Type / N°
Rev.
Fw
Date
Page
Total pages
EW055.600D
D
4L
6
th
June 2018
25
43
EsiWelma
®
s.r.l.
MC
Meter zero setting
- This procedure allows to set the mass flow meter
to zero. By placing the MC parameter to 1, the
computing head automatically provides, at the end
of the set-up, to perform the zero setting of the
mass flow meter. At the end of the procedure it
resets the parameter to 0.
PS
Specific weight
- This value must be inserted to convert from Kg to
Smc. The value does not include the initial 0.
(e.g.: For a weight of 0,7174 insert only 7174)
(
The parameter is visible only if the Jumper
JP1, that allows the delivery in Smc, has been
set
)
P1
Preset value push button 1
- Preset value used by the computing head when
button 1 is pressed. It can be programmed in € or
local currency for the amounts. Delivered fuel
value is however 1Kg o Smc.
P2
Preset value push button 2
- Preset value used by the computing head when
button 2 is pressed.
It can be programmed in € or
local currency for the amounts. Delivered fuel
value is however 10Kg o Smc.
CF
Conversion rate currency/€
- Value to be inserted to convert the amount
visualization from local currency to Euro. The
conversion rate is
modifiable only when the
computing head is switched on.
To exit the SETUP procedure, operator has to set JP2 Jumper “open”.
Delivery is not possible if JP2 Jumper is “closed” in SETUP.