Type / N°
Rev.
Fw
Date
Page
Total pages
EW055.600D
D
4L
6
th
June 2018
29
43
EsiWelma
®
s.r.l.
4.2.5 Price change
After pressing red «S» button and entering the set-up, the
computing head asks for password; if it has not been previously
modified, its default value is 10000. To enter the exact code, follow
the procedure below:
Push black «t» button until the correct value of the first
digitis reached
Press red «S» button to pass to the next digit.
Once inserted the correct value also for the last digit, press
red «S» button again to enter set-up.
Figure 22:
Inserting Password
It is not necessary to set the Jumper J2 to enter the Price changing procedure,
because the operation is not considered metrically relevant
.
If password is not correct the computing head immediately exits the set-up procedure and
returns to stand-by mode.
If password is correct, the unit price can be updated. The operating sequence is similar to the
already described above:
Push red
«S»
button to select the digit to modify
Push black
«t»
button until the desired value is obtained
Push green
«U» button to exit the price changing procedure.
At the end of set-up the computing head asks if the password should be changed and waits
for an answer:
y
es o
n
o.
Push black button to confirm the password changing intention.
Push green button to exit without modifying the password.
Figure 23:
Password changing request
In case of negative answer the procedure will end with the
saving of the new unit price.
Figure 24:
Visualization saving unit price
p.u.
Kg
p.u.
Kg
p.u.
Kg