Type / N°
Rev.
Fw
Date
Page
Total pages
EW055.600D
D
4L
6
th
June 2018
20
43
EsiWelma
®
s.r.l.
The following table shows all the available parameters:
Computing head set-up parameters
Code
Imprint
Signification
Range
Step
Default
Units
01
LF
Functioning level
1-3
1
2
----
02
St
Functionality Electro valve 1
0-3
1
0
----
03
Mt
Meter type
0-3
1
3
----
04
Sb
ModBus communication baud rate
0-3
1
0
----
05
L0
Low flow rate 1
st
...2
nd
level (stop for mono-level) 1-16
1
2
10g
06
t0
Acquisition delay for L0
0-15
1
8
s
07
L1
Low flow rate 2
nd
…3
rd
level (stop for bi-level)
1-16
1
1
10g
08
t1
Acquisition delay for L1
0-15
1
12
s
09
L2
Low flow rate 3
rd
level (stop delivery)
1-16
1
1
10g
10
t2
Acquisition delay for L2
0-15
1
12
s
11
AL
LAN address
1-32
1
1
----
12
HF
High flow rate
1-299
1
150
10g/s
13
AP
Enables the pressure switch
0-15
1
12
----
14
AC
Enables the pressure compensation
0-1
1
0
----
15
HP
Pressure switch intervening values
200-299
1
235
barg
16
Pcon
Compensation pressure
150-250
1
207
barg
17
tC
Compesation temperature
0
– 50
1
21
°C
18
Ot
Temperature offset
± 20
1
10
°C
19
tF
Duration of the first puff
2-60
1
4
s
20
tS
Duration of the second puff
1-30
1
10
s
21
dr
Awaiting reading
1-40
1
10
s
22
Po
POS option
0-2
1
0
----
23
Pr
Kind of preset
0-2
1
0
----
24
bP
Slowdown (low flow)
0-90
10
50
10g
25
cA
Early closure of the solenid valve
0-11
1
6
10g
26
cM
Hose compensation in preset mode
0-10
1
5
10g
27
tP
Nozzle switch acquisition time
0-10
1
1
s
28
FC
Holding time of the count beyond the stop
0-40
5
30
0.1s
29
PL
Protocol Level
1-4
1
4
----
30
PC
Pressure switch contact polarity
0-1
1
0
----
31
Ar
Amount approximation
0-3
1
3
----
32
DP
Unit price decimal digits
0-3
1
3
----
33
DI
Amount decimal digits
0-3
1
2
----
34
Ct
Passage to round digit
1-3
1
1
----
35
nd
Number of connected displays
1-2
1
1
----
36
CE
Number of delivered display digits
5-6
1
5
----
37
bL
Delivery stop for LAN error
0-1
1
0
----
38
MC
Flow meter zero setting procedure
0-1
1
0
----
39
PS
Specific weight
255-9999
1
7000
----
40
P1
Preset value push button 1
0-9/dig
1
10
€
41
P2
Preset value push button 2
0-9/dig
1
5
€
42
CF
Conversion factor currency / €
0.1-9.99999 1
6.55957
----