23
5.
Wrap the mica on the new heater element and insert into the steel tube. It is better to right insert into the steel
tube and cut off the unwanted mica.
CAUTION:
The sensor cords of heater element putting on the red and yellow hot shrinking tubes are on
the opposite part of the ground cord.
6. Reassemble the handle according to the opposite order of disassembling. The heater part of the heater element
must be insert into the end. The sensor cord has polarity and it must connect with the same color.
9.4 Replace the Fuse
1.
Unplug the power cord from the power receptacle.
2.
Remove the fuse holder and take out the broken fuse.
3.
Replace the fuse. Put the fuse holder back in place.