8.8.7 Communication Cycle Period (1006
h
)
INDEX
1006
h
Name
Communication Cylcle Period
Data type
unsigned 32
Access mode
rw
Default value
0
w
s
This object contains the cycle time of the SYNC frames.
Index
Sub-
index
Description
Value range
Default
value
Data type
Access
mode
1006
h
0
communication cycle period
0,
0000 01F4
h
...
FFFF FFFF
h
0
w
s
unsigned 32
rw
communication cycle period Cycle time of the SYNC frame in [
w
s].
If the value is ‘0’ no SYNC messages are transmitted.