![ESD C.3055.02 Скачать руководство пользователя страница 53](http://html.mh-extra.com/html/esd/c-3055-02/c-3055-02_manual_2426454053.webp)
CANopen Firmware
CAN-CBX-COM2
Manual • Doc.-No.: C.3055.21 / Rev. 1.1
Page 53 of 125
8.5 Overview of used CANopen-Identifiers
Function
Identifier
Description
Network management 0
NMT
SYNC
80
h
SYNC to all, (configurable via object 1005
h
)
Emergency Message
80
h
+ NodeID
configurable via object 1014
h
RPDO1
200
h
+ NodeID
PDO1 to CAN-CBX-COM2
(Receive-PDO1 COM A)
TPDO1
180
h
+ NodeID
PDO1 to CAN-CBX-COM2 (object 1801
h
)
(Transmit-PDO1 COM A)
RPDO3
400
h
+ NodeID
PDO3 to CAN-CBX-COM2
(Receive-PDO3 COM B)
TPDO3
380
h
+ NodeID
PDO3 to CAN-CBX-COM2 (object 1802
h
)
(Transmit-PDO3 COM B)
Client-SDO
580
h
+ NodeID
SDO to CAN-CBX-COM2 (Tx)
Server-SDO
600
h
+ NodeID
SDO to CAN-CBX-COM2 (Rx)
Node Guarding
700
h
+ NodeID
not configurable
NodeID: CANopen address [1
h
...7F
h
]
8.5.1 Setting the COB-ID
The COB-IDs which can be set (except the one of SYNC), are deduced initially from the setting of the
Node-ID via the coding switches (see page 17). If the COB-IDs are set via SDO, this setting is valid
even if the coding switches are set to another Node-ID after that.
To accept the Node-ID from the coding switches again, the Comm defaults or all defaults have to be
restored (object 1011
h
)