4. Technical Data
4.1 General technical Data
Power supply voltage
nominal voltage:
24 V/DC
input voltage range:
24 V ±20%
current consumption (24 V, 20
f
C): 30 mA
Connectors
24V
(4-pin PCB plug connector with spring-cage connection,
X100 ) - 24V-power supply voltage
COM A
(7-pin PCB plug connector, X300)
- Serial interface 1
COM B
(7-pin PCB plug connector, X310)
- Serial interface 2
CAN
(5-pin PCB plug connector, X400) - CAN interface
InRailBus (5-pin TBUS-connector, X101) - CAN interface and power
supply voltage via InRailBus
Only for test and programming purposes (internal):
X220
(10-pin socket connector)
Temperature range
0
f
C ... +60
f
C ambient temperature
Humidity
max. 90%, non-condensing
Protection class
IP20
Pollution degree
maximum permissible according to DIN EN 61131-2:
Pollution Degree 2
Housing
Plastic housing for carrier rail mounting NS35/7,5 DIN EN 60715
Dimensions
width: 22.5 mm, height: 99 mm, depth: 114.5 mm (without connectors)
Weight
approx. 135 g
Table 9: General technical data