![ESD C.3055.02 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/esd/c-3055-02/c-3055-02_manual_2426454020.webp)
Technical Data
Manual • Doc.-No.: C.3055.21 / Rev. 1.1
CAN-CBX-COM2
Page 20 of 125
4.2 CPU
CPU
32 bit
g
C LPC2119FBD64
RAM
16 Kbyte integrated
Flash
128 Kbyte integrated
EEPROM
4 Kbyte
Table 10: Microcontroller
4.3 CAN Interface
Number
1
Connection
5-pin PCB plug connector with spring-cage connection
or via InRailBus-connector (CAN-CBX-TBUS )
CAN Controller
integrated in LPC2119FBD64, ISO11898-1
Electrical isolation of CAN
interfaces against other units
Isolation voltage U: 500 V
(= withstand-impulse voltage according to DIN EN 60664-1)
Physical layer CAN
physical layer according to ISO 11898-2, transfer rate
programmable from 10 Kbit/s up to 1 Mbit/s
Bus termination
has to be set externally if required
Table 11: Data of the CAN interface