background image

 

 
 

iLog User Guide 

 

 

 

 

14 

The  second  window  displayed  is  the  ‘Configure  Sensors  –  Specification’  window  (see  figure 
1.11).  This  window  provides  you  with  the  ability  to  add  and  adjust  your  sensor(s)  out  of 
specification  settings  and  the  increment  in  which  your  ESCORT  Console  software  will  display 
changes in your logger readings.    
  
 

 

 

Figure 1.11 – ‘Configure Sensors – Specification’ window 
 

Change your sensor settings by applying the required 
temperatures to the text boxes or using the scrolling 
arrows located to the right  

Содержание iLog

Страница 1: ......

Страница 2: ...swords 10 Connecting a sensor 11 Configuring logger sensors 11 Setting a date and time 17 Setting start conditions 18 Logger summary 19 Program window 20 Bookmarking 22 Downloading your iLog logger 23...

Страница 3: ...onditions Your iLog logger is not to be subjected to a naked flame Exposures to such conditions may result in damage to your iLog logger and result in an explosion of the battery Never operate your iL...

Страница 4: ...pened and the warranty seal is broken your iLog logger is no longer covered by warranty This includes the replacement of your logger s battery Only subject your iLog logger external sensor s to temper...

Страница 5: ...he logger via magnet swipe or pre program to start at a specific date and time Logging interval as low as 1 second per reading and as high as one day 24 hours User replaceable battery To replace the b...

Страница 6: ...nize the new hardware USB device Windows 98 and 2000 Follow Installation Manual delivered with the adapter Simplified instructions for JA USB SER Restart you computer Plug in the USB Serial cable into...

Страница 7: ...SB to serial port converter you may have to look up the correct COM port number in your Device Manager Select the iLog tick box as one of the ESCORT products you want to use This dialog appears automa...

Страница 8: ...ee below Once you have opened the Program and Configure wizard a welcome screen will appear see figure 1 4 If you do not wish to see this message when downloading future loggers select the Do not remi...

Страница 9: ...w the description heading will not be checked and you will not be able to proceed If your logger is password protected you will be prompted for the password upon selecting the tick box To proceed to t...

Страница 10: ...7 Here you are given two options the Protect program settings option which provides for the protection of the programming settings you have issued for you logger The second option is the Protect retr...

Страница 11: ...he left and or the right side s of the logger see figure 1 8 Configuring logger sensors Following the Details window is the Sensors window which allows for the selection and configuration of you iLog...

Страница 12: ...left corner of the Program and Configure window To select multiple sensors hold the control key located on your computers keyboard down and select the appropriate sensors Once you have selected the Co...

Страница 13: ...ific information relating to you logger and allows for the addition of logger description for easy logger identification Once you have entered a description and checked your sensor s information click...

Страница 14: ...to add and adjust your sensor s out of specification settings and the increment in which your ESCORT Console software will display changes in your logger readings Figure 1 11 Configure Sensors Specif...

Страница 15: ...f specification readings or consecutive readings out of specification that a logger records before generating an alarm simply select the appropriate tick box and enter the required number into the tex...

Страница 16: ...sor s readings on display tick box You also have the ability to select the unit of temperature you would prefer and the number of seconds that your logger will pause for before advancing to the next d...

Страница 17: ...dates your logger with you computers current clock settings The final option allows you to manually enter a date and time for your logger To manually change your clock settings simply select the scrol...

Страница 18: ...start enter your logger finish date and time select whether you require continuous background logging and provides the ability to enable the beeper within the logger Figure 1 15 Program and Configure...

Страница 19: ...ndow see figure 1 16 which provides a brief summary of you iLog s startup settings Once you have checked that your logger s settings are correct simply click the Program button Figure 1 16 Program and...

Страница 20: ...e your logger has been programmed the Program and Configure wizard will allow you to program additional loggers with the same settings To do this simply click the Program and Configure addition device...

Страница 21: ...r Guide 21 Figure 1 18 Program and Configure Program window Select this tick box to program additional loggers with the same settings and select the Next button which will appear once the tick box is...

Страница 22: ...kmark logger readings by swiping a magnet over the iLog s label Once your iLog is downloaded your ESCORT Console software will highlight bookmarked readings using the colour green see figure 1 19 Figu...

Страница 23: ...screen will appear see figure 2 1 If your logger has been recording and has information saved within its memory a tick box will be checked to the left of the iLog icon If the tick box is not checked...

Страница 24: ...place see figure 2 2 Once the wizard has successfully downloaded your logger the Next button located at he button of the window will become available simply select the Next button to proceed If a log...

Страница 25: ...iLog User Guide 25 Figure 2 3 Download Unsuccessful search window Select the search button to reattempt logger download...

Страница 26: ...the start setting requires specific date and or time simply use the scrolling arrows located to the right of the appropriate text box see figure 1 4 Once you have assigned the appropriate start condi...

Страница 27: ...5 This window is helpful when you have more than one logger to download To use this function select the Download information for additional Loggers and or ChartReaders tick box and select the next but...

Страница 28: ...ampling interval the number of readings recorded the temperature range it recorded within the alarm limits and the highest lowest and average readings Figure 3 1 Downloaded file Below the information...

Страница 29: ...electing double click to select from the views menu located on the left of your Console window Figure 3 3 Different views List of readings The first option under the readings menu is the list of readi...

Страница 30: ...5 Readings and Summary 2D Line graph The first menu option under the 2D Graph menu is the line graph menu option Here your logger data is displayed in an easy to view format with each sensor displayed...

Страница 31: ...gure 3 6 Step Graph Summary Overview The first menu option under the Summary menu is the Overview menu option This menu option provides the basic information relating to your downloaded logger file su...

Страница 32: ...ating to your logger file including your loggers serial number description and average highest and lowest readings Figure 3 8 Statistics Analysis The third menu option under the Summary menu is the An...

Страница 33: ...of Specification Note For detailed information regarding the operation of ESCORT Console please refer to the help guide provided within the software You can access the help menu via the dropdown menu...

Страница 34: ...you accidentally remove the humidity sensor and bung from the iLog case you can reinsert the sensor using the guide hole in the PCB Printed Circuit Board 4 Move the battery located within the battery...

Страница 35: ...h a foreign object e g fingers it is vital that the sensor is cleaned with a cleaning solution We recommend that a cleaning solution which is 50 isopropyl alcohol IPA and 50 water is used to clean the...

Страница 36: ...y 32 000 readings Resolution 0 1 C 0 2 F Accuracy 0 3 C LCD Software programmable LED s Active and Alarm Data Recovery Via standard ESCORT PC interface and ESCORT Console software Size Diameter 76mm h...

Страница 37: ...Logging Systems Ltd will not accept any freight charges for goods that have been returned without ESCORT Data Logging Systems Ltd s expressed permission Customers and distributors may return product...

Страница 38: ...ing Systems products please contact us at ESCORT Data Logging Systems Ltd PO Box 15 639 New Lynn Auckland New Zealand Tel 0064 9 826 0960 Fax 0064 9 826 0285 Email mail escortdls com Alternatively you...

Отзывы: