2.1  Product Identification and Shipping List 

The SuiteSentry Single Screener hardware is shipped in one corrugated carton. This long carton 

contains all the items required for assembly and installation of the SuiteSentry Single Screener 
System. The contents are listed below.  
 

Component 

Qty 

 P/N 

SuiteSentry Single Screener 

- Sensor Array Column Assembly  

1 400151 

Power Supply - Digital w/ 12’ output cable / connector 

9910-A-01427-C 

AC mains power cord – w/ 90° Plug - 3 ft long -- USA 

6608-A-01497-A 

Installation Hardware Kit  - SuiteSentry Single Screener  

9993-A-02760-A 

Surface Conduit Accessory Kit – Ivory – SuiteSentry Single Screener  

9993-A-02041-B 

Document Package – SuiteSentry Single Screener 

0550-A-02016-D 

Spacer, Mounting Block Extension 

2973-A-02778 

Mat, Floor, Solo Instructive 

0540-A-02050 

Box, Return Materials, 14” x 8” x 5” (w/ UPS Return Label) 

2840-A-02838 

 

2.2  Tools Required for Assembly and Installation 

 

1.

 

#2 Phillips screwdriver 6 inches long (15 cm) 

2.

 

Box cutting knife with replacement blades 

1.

 

Medium duty electric or battery drill with at least 2 spare charged batteries 

2.

 

1/4 inch nut driver/1/4 inch wrench (ratcheting wrench is best) 

3.

 

3/8 inch nut driver/3/8 inch wrench (ratcheting wrench is best) 

4.

 

Drill bit index with at least two (2) 1/8 inch drill bits and ½ inch bit for wall togglers 

5.

 

Measuring tape up to 12 feet (4 meters) 

6.

 

Micro screwdrivers, flat head and Phillips 

7.

 

6 inch (15 cm) bubble level 

8.

 

Heavy Duty PVC cutters for wire trim moldings 

(Sears 3-1 Accu-Cut Model 37310 recommended)

 

9.

 

Painter’s tape (for detector) and clear packing tape (for parts return box) 

 

 

Содержание ETS-LINDGREN SuiteSentry

Страница 1: ...SuiteSentry Single Screener Operation and Installation Manual September 2018 PNPNPNP Rev A...

Страница 2: ...Page 2 of 34...

Страница 3: ...y Single Screener 11 Reference Documents Installation Wiring Diagram 14 4 2 Power Up and Diagnostic Instructions 18 5 0 OPERATION PROCEDURES 19 5 1 General Description of Operation of SuiteSentry Sing...

Страница 4: ...m FMD Ferromagnetic Detector LED Light Emitting Diode electronic replacement for lamp PIR Passive Infra Red Detects body heat and motion and enables SuiteSentry Single Screener to go into Active Mode...

Страница 5: ...ektrische Schl ge mechanische oder sonstige Gefahren kommen AVISO Este Manual de Servicio s lo existe en ingl s Si alg n proveedor de servicios ajeno a KDI solicita un idioma que no sea el ingl s es r...

Страница 6: ...y attracts anything which is ferromagnetic generally containing iron or steel It can and will attract and pull any ferromagnetic object such as hand tools oxygen bottles scissors chairs IV stands and...

Страница 7: ...ntry Single Screener 1 0550 A 02016 D Spacer Mounting Block Extension 2 2973 A 02778 Mat Floor Solo Instructive 1 0540 A 02050 Box Return Materials 14 x 8 x 5 w UPS Return Label 1 2840 A 02838 2 2 Too...

Страница 8: ...ctor SAP Only if facility permits ask first 8 Clean area and remove installation debris 9 Train the MRI staff and have them sign provided Training Record roster 10 Take pictures of installed detector...

Страница 9: ...on limitations with regard to locating ferromagnetic material inside an object or human body Therefore if a ferrous non superficial or subcutaneous object is detected further investigation is recommen...

Страница 10: ...ns Usage The highest sensitivity to moving objects occurs within 3 inches of the Sensor Array Column All efforts should be made to minimize traffic in the area of the Sensor Array Column during the sc...

Страница 11: ...ener Bottom Cap Rear and the line cord into the outlet slide SuiteSentry Single Screener away from shipping carton if you need to plug the supply cable in to the bottom cap receptacle SEE Fig 1 2 and...

Страница 12: ...2 inches to more easily attach power input Remove power supply and main power cable to power up the detector for operation verification prior to permanent mounting Rigid Foam Support Blocks for shipp...

Страница 13: ...e Wall Toggler This is a heavy duty toggle bolt kit included in the shipment Part 2186 A 02053 It requires a drill bit not provided and instructions are included This is the recommended mounting when...

Страница 14: ...Page 14 of 34 Reference Documents Installation Wiring Diagram Figure 5 Typical Installation Figure 4 Drill Locations for Mounting Brackets Ferromagnetic Detector Mounted to Wall...

Страница 15: ...h to wall and catch the debris from drilling the large hole Hold ends of straps between thumb and forefinger and pull toward you until channel rests flush behind wall Slide plastic cap along straps wi...

Страница 16: ...Figure 8 Exploded view of Mounting Block toggle screw and washer into wall Figure 9 a b c d Exploded views of Mounting Block Mtg Block Extension over Rub Rail NOTE The togglers are very strong and DO...

Страница 17: ...creener forward slightly and insert the Power Cable into the connector at the rear of the SuiteSentry Single Screener 4 Insert the bottom cross screw in the same manner 5 Use the Digital Power Supply...

Страница 18: ...n beeping the of beeps indicates sensitivity setting the fewer of beeps the higher the sensitivity setting 2 The purple power on LED indicator at top upper bar graph display illuminates 3 Followed by...

Страница 19: ...the object person is within the adjustable physical presence area approx 6 10 in front of the detector As person moves in to the sensing area the PIR will detect your proximity and cause the system t...

Страница 20: ...Page 20 of 34 SuiteSentry Single Screener 3 Modes of Operation Figure 12 FerrAlert Solo 3 Modes of Operation...

Страница 21: ...on the Sensor Array Column at the location within a few inches of the detected ferromagnetic hazard Additionally an indicator at the top of the array aids the supervisor to see the location of the fe...

Страница 22: ...Page 22 of 34 SuiteSentry Single Screener Operation Usage Figures 13 a b c SuiteSentry Single Screener Operation and Usage...

Страница 23: ...L Adjusts the ferromagnetic disturbance threshold required to trigger an alarm Sensitivity increases with clockwise rotation Sensitivity control shown in the initial detent position Switch 1 Activates...

Страница 24: ...he adjustment to verify alarm is functional You may shut the alarm off temporarily while adjusting sensitivity 3 Begin by noting the current setting of the SENSITIVITY control as the original setting...

Страница 25: ...light radiating from personnel moving in its field of view Movement of a person and not an object causes the SuiteSentry Single Screener to change from STANDBY non alarming mode to ACTIVE ready to ala...

Страница 26: ...c illumination done sequentially This takes approx 45 seconds With that established The actual sensors are 3 above and 3 below each green led in the column Take a post it piece of paper and fold it in...

Страница 27: ...unted or free standing with optional Mobile Base using internal battery power while un plugged and recharges or operates on wall power when plugged in POWER REQUIREMENT 100 to 240 VAC 47 to 63 Hz 30 w...

Страница 28: ...Page 28 of 34 9 3 Reference Documents Installation Wiring Diagram SuiteSentry Single Screener Installation Wiring and Figure 16 Typical Installation Ferromagnetic Detector Mounted to Wall...

Страница 29: ...Page 29 of 34 9 4 Mounting Dimensions SuiteSentry Single Screener...

Страница 30: ...Page 30 of 34 10 0 Typical Installation Pictures...

Страница 31: ...ge 31 of 34 Typical Installation Pictures continued The cable can be run up the back of the SuiteSentry Single Screener and inside the 2 Mounting Block Brackets for a neat install when outlet is up ne...

Страница 32: ...Page 32 of 34 Typical Installation Pictures continued...

Страница 33: ...luding but not limited to implied warranties of merchantability and fitness for a particular purpose ETS Lindgren shall not be subject to any other obligations or liability whatsoever with equipment m...

Страница 34: ......