SPECIFICATIONS,
CLASSIFICATION
&
REFERENCE
DOCUMENTS
9.1 Specifications
NUMBER OF DETECTION ZONES:
Six (6)
HEIGHT OF UNIFORM SENSITIVITY:
Greater than six (6) feet
HAZARD LOCATION INDICATORS:
Four (4) amber flashing lights at height of the hazardous ferrous
object and one (1) in the Top Control Panel display.
AMBIENT MAGNETIC DISTURBANCE INDICATOR:
Eight (8) blue LED bars in the top display
FERROMAGNETIC HAZARD SENSITIVITY:
Adjustable
AUDIO INDICATOR:
Selectable, adjustable volume
MOUNTING:
Wall mounted or free-standing with optional Mobile Base
using internal battery power while un-plugged and recharges or
operates on wall power when plugged in.
POWER REQUIREMENT:
100 to 240 VAC, 47 to 63 Hz, 30 watts
DIMENSIONS:
Height: 86 ¼” (220 cm),
Depth from wall: 3 ¾” (9.525 cm)
Width: 2¼” (5.8 cm)
9.2 Device Classification
This equipment is classified as follows:
Safe Extra Low Voltage (SELV)
- exterior case is grounded only for shielding purposes.
Ordinary equipment
- exterior case is enclosed but is not water-proof.
The equipment may be disinfected by denatured alcohol applied
externally
.
The equipment is
not
suitable
for use in the presence of flammable anesthetic mixture.
The equipment may be used in
continuous operation
.
Содержание ETS-LINDGREN SuiteSentry
Страница 1: ...SuiteSentry Single Screener Operation and Installation Manual September 2018 PNPNPNP Rev A...
Страница 2: ...Page 2 of 34...
Страница 20: ...Page 20 of 34 SuiteSentry Single Screener 3 Modes of Operation Figure 12 FerrAlert Solo 3 Modes of Operation...
Страница 29: ...Page 29 of 34 9 4 Mounting Dimensions SuiteSentry Single Screener...
Страница 30: ...Page 30 of 34 10 0 Typical Installation Pictures...
Страница 32: ...Page 32 of 34 Typical Installation Pictures continued...
Страница 34: ......