background image

 

G8872_1 Installation Manual AUS 

 

8

Replacing Electronic Draw 

All of the electronic components of the heater have been located on a removable draw. 
This draw is located on the left hand outer side of the IB850 and under the front burner of the 
IB600. On the back of the draw are two large connectors that unplug as the draw is removed so 
only the three wires connecting the electronics to the igniters and flame rod must be removed 
manually from the PCB (Printed Circuit Board). 
 

ISOLATE THE POWER TO THE FIRE BEFORE PROCEEDURE.

 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

Step Two: 

Take out the two screws at each end of the electronic draw and pull draw directly outwards

 

 
 

 

 

 

 

 
 

 
 
 
 

Step 

Three: 

    

Carefully remove the two wires shown  
from the white ignition module. 

 
 
 
 
 
 
 

IB600

 = Remove the bottom 

fascia trim panel

 

Step one: 
IB850

 = Remove outer fascia  

by taking out two screws located  
behind the bottom fascia trim panel

 

 

1.

 Flame Rod

2.

 Spark Lead

Wire Entry:

 

IB850

IB600

Содержание IB600

Страница 1: ...ried out only by a suitably qualified and trained person Gas and electricity supply MUST be isolated before any service operation is carried out on this appliance This manual must be left with the app...

Страница 2: ...ents Page Error Codes 3 Cleaning the Log Set and Glass 5 Checking Operating Pressure 6 Removing Cleaning Fan 7 Removing Electronic Draw 8 Replacing a Wireless Control 9 Gas Type Conversion 10 Annual S...

Страница 3: ...ment in relation to the flame Ensure it is well enveloped in flame as per the diagram in the installation instructions Ensure no coals have dropped onto the ignition electrodes between the burners Ens...

Страница 4: ...gain after a few seconds Valve Temp Sensor Trip The valve temperature sensor has detected abnormally high temperatures around the valves This is an unlikely fault and should it occur please contact th...

Страница 5: ...eposition log set so that front edge of each log is just behind each row of holes in burner top Clear any blockage from primary air port of burner Check to make sure flue system is drawing well Step 1...

Страница 6: ...tallation pipe size or upstream regulator settings Replace inlet test point screw 3 Remove the operating pressure test point screw Connect manometer tube and measure pressure with heater running on fu...

Страница 7: ...THE FIRE BEFORE PROCEEDURE Remove front glass and log set as described on page 5 Step Two Remove fire box from heater by taking out the screws from each corner and Pulling fire directly outwards as sh...

Страница 8: ...ee wires connecting the electronics to the igniters and flame rod must be removed manually from the PCB Printed Circuit Board ISOLATE THE POWER TO THE FIRE BEFORE PROCEEDURE Step Two Take out the two...

Страница 9: ...tinguish the fire 4 Immediately after releasing the Aux On Off button turn on the remote control and wait four to five minutes During this time the fire will re ignite NOTE During this period the fire...

Страница 10: ...Step Three Unscrew rear burner clamp bracket On left side Lift out the rear burner Step Four Change the three jets with the jets supplied in kitset Replace the rear burner and clamp bracket Replace f...

Страница 11: ...dust from the cavity that houses the fan and solenoid valves and from the ducts down each side of the heater that lead to this cavity 8 Test all joints for gas tightness 9 Reassemble heater and check...

Страница 12: ...G8872_1 Installation Manual AUS 12 Wiring Diagram...