background image

G8872_1 Service Manual AUS 

 

 

 

 

 

 
 

 

IB850 and IB600 

Service Manual 

 AUSTRALIAN EDITION 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Important 

  This appliance should be serviced every 12 to 24 months 

  Any service operation should be carried out only by a suitably qualified and trained person 

  Gas and electricity supply MUST be isolated before any service operation is carried out  

on this appliance. 

  This manual must be left with the appliance. 

 

Manufactured by: Escea Ltd, PO Box 5277 Dunedin NZ, Ph: 03 479 0302, e: 

[email protected]

 

Distributed by: Glen Dimplex, Unit 2 205 Abbotts Road, Dandenong, Melbourne. Ph: +61 3 87873567 

Содержание IB600

Страница 1: ...ried out only by a suitably qualified and trained person Gas and electricity supply MUST be isolated before any service operation is carried out on this appliance This manual must be left with the app...

Страница 2: ...ents Page Error Codes 3 Cleaning the Log Set and Glass 5 Checking Operating Pressure 6 Removing Cleaning Fan 7 Removing Electronic Draw 8 Replacing a Wireless Control 9 Gas Type Conversion 10 Annual S...

Страница 3: ...ment in relation to the flame Ensure it is well enveloped in flame as per the diagram in the installation instructions Ensure no coals have dropped onto the ignition electrodes between the burners Ens...

Страница 4: ...gain after a few seconds Valve Temp Sensor Trip The valve temperature sensor has detected abnormally high temperatures around the valves This is an unlikely fault and should it occur please contact th...

Страница 5: ...eposition log set so that front edge of each log is just behind each row of holes in burner top Clear any blockage from primary air port of burner Check to make sure flue system is drawing well Step 1...

Страница 6: ...tallation pipe size or upstream regulator settings Replace inlet test point screw 3 Remove the operating pressure test point screw Connect manometer tube and measure pressure with heater running on fu...

Страница 7: ...THE FIRE BEFORE PROCEEDURE Remove front glass and log set as described on page 5 Step Two Remove fire box from heater by taking out the screws from each corner and Pulling fire directly outwards as sh...

Страница 8: ...ee wires connecting the electronics to the igniters and flame rod must be removed manually from the PCB Printed Circuit Board ISOLATE THE POWER TO THE FIRE BEFORE PROCEEDURE Step Two Take out the two...

Страница 9: ...tinguish the fire 4 Immediately after releasing the Aux On Off button turn on the remote control and wait four to five minutes During this time the fire will re ignite NOTE During this period the fire...

Страница 10: ...Step Three Unscrew rear burner clamp bracket On left side Lift out the rear burner Step Four Change the three jets with the jets supplied in kitset Replace the rear burner and clamp bracket Replace f...

Страница 11: ...dust from the cavity that houses the fan and solenoid valves and from the ducts down each side of the heater that lead to this cavity 8 Test all joints for gas tightness 9 Reassemble heater and check...

Страница 12: ...G8872_1 Installation Manual AUS 12 Wiring Diagram...