This appliance is supplied set up for Natural 
Gas usage. A conversion kit is included with the 
product for Universal LPG usage. The conversion 
kit contains the appropriate injectors, 1 Brass Test 
Point and 1 LPG sticker.

Please follow the procedure below if a conversion 
to suit UNIVERSAL LPG is required:
•  Remove the hotplate trivets, burner caps and 

burner crowns to access the hotplate injectors. 
Replace the factory fitted injectors with the 
appropriate injectors, as supplied. Refer to 
injector orifice table for injector sizes. The 
injector size is stamped on the side of the 
injector.

•  Connect the brass test point adapter (pictured 

opposite) using approved gas thread tape or 
compound to the elbow fitting.

•  Turn on the gas supply and at each new 

connection check for leaks using soapy water. 
Each hotplate valve should be turned on, one 
at a time, and the injector hole blanked off for 
several seconds.

•  With the appliance operating check the  

outlet pressure when all burners of the 
appliance are operating at maximum, when  
the smallest burner of the appliance is 
operating at minimum.  
Under these conditions the outlet pressure 
should not vary from the nominal outlet 
pressure of 2.60kPa by more than ±0.52kPa.

•  If the regulator appears to not be performing 

satisfactorily then check the following points:

•  If the outlet pressure is consistently too low 

then the inlet pressure may be too low and 
adjustment of an upstream regulator may be 
needed, or an upstream regulator or valve with 
insufficient flow capacity may be present in the 
gas supply line.

•  If this is suspected then it may be necessary to 

repeat the checks whilst measuring both the 
inlet and outlet pressure to determine if the 
inlet pressure is in the range 2.75 – 7.00kPa.

•  One by one, turn the knobs to minimum and 

screw in the bypass screw (accessible when 
the knob is removed) until a small stable flame 
results; a length of 3-4mm. Turn the knob to 
maximum and then back to minimum to ensure 
that the correct minimum flame is maintained.

•  Attach the LPG sticker to the cooker, near the 

gas supply inlet. Cover the Natural Gas label 
that is factory fitted.

LPG Conversion

Содержание ECG604E

Страница 1: ...Version V1 0 1022 Everything you need for your Gas Cooktop is in this User Manual Model s ECG604E...

Страница 2: ...e our Support Team are here to help You can use our online Support Centre at anytime by visiting http support residentiagroup com au Or you can contact us via phone by dialing 1300 11 HELP 4357 It is...

Страница 3: ...age 8 Using Your Cooktop Page 9 Burners Page 10 Cleaning Care Page 11 Troubleshooting Page 12 Technical Data Page 13 Installation Instructions Page 16 Gas Connection Page 19 LPG Conversion Page 20 Ele...

Страница 4: ...nded and may cause fire electric shock or personal injury Attachments The use of attachments is not recommended by the appliance manufacturer and distributor as they may be hazardous Improper use Dama...

Страница 5: ...are centrally located on the trivets Handles should be turned away from the front of the bench to avoid accidents Do not modify this appliance Only models fitted with flame safeguard can be used in m...

Страница 6: ...ifferently YOUR Cooktop Figure 1A ECG604E A B D E C E F KEY A Stainless Steel Hob B Burner Control Knobs C Enamel Trivets D Auxiliary Burner E Semi Rapid Burner F Rapid Burner COOKTOP COMPONENTS ACCES...

Страница 7: ...CING Servicing MUST only be carried out by authorised personnel To maintain safe operation it is recommended that the product be inspected every five years by an authorised service person If the suppl...

Страница 8: ...ght within 5 seconds turn knob to OFF position wait to allow gas to disperse and then try lighting again Burners MUST be operated between 1 and 9 settings only To light a burner the knob must be turne...

Страница 9: ...ous boil will not cook food any faster and will waste energy Figure 4 POTS AND PANS All common pots and pans aluminium stainless steel cast iron ceramic etc may be used on your new gas cooktop Ensure...

Страница 10: ...of cleaner directly onto the hob Rub clean using a damp cloth or paper towels Use a damp cloth to remove all remaining traces of the cleaner which could otherwise burn on when the hob is next used Wi...

Страница 11: ...lean ignition spark plugs No spark is obtained when control knob is activated Electricity supply is disconnected or switched off Switch on electricity or check fuses Ignition spark plugs wet or dirty...

Страница 12: ...conversion kit supplied COOKTOP PHYSICAL DIMENSIONS mm Width 600 Depth 510 Height 95 CUT OUT DIMENSIONS mm Width 560 Depth 490 ENERGY RATING NG MJ h Auxiliary burner 4 3 Semi Rapid burner 2 6 3 Rapid...

Страница 13: ...appliances Check the dimensions of the appliance as well as the dimensions of the gap to be cut in the kitchen unit The panels located above the work surface directly next to the appliance must be mad...

Страница 14: ...is 10mm The edges of the hob must be a minimum distance of mm from a side or rear wall 700 mm between the highest point of the hob surface including the burners and the underside of any horizontal su...

Страница 15: ...nstallation Remove any excess seal visible after installation WARNING Failure to fix the cooktop to the bench could result in loosening of the gas connection through movement of the cooktop and a gas...

Страница 16: ...ooktop in accordance with AS NZS 5601 1 in particular section 5 9 and clause 6 10 1 8 or AS NZS 5601 2 in particular section 2 11 Where a hose assembly is used and the cooktop is in the installed posi...

Страница 17: ...is a parallel thread and is connected to consumer piping or hose assembly Regulators are supplied pre adjusted and configured by the component maker for use with Natural Gas The appliance installer i...

Страница 18: ...w then the inlet pressure may be too low and adjustment of an upstream regulator may be needed or an upstream regulator or valve with insufficient flow capacity may be present in the gas supply line I...

Страница 19: ...e when all burners of the appliance are operating at maximum when the smallest burner of the appliance is operating at minimum Under these conditions the outlet pressure should not vary from the nomin...

Страница 20: ...de 1 Green Yellow Earth 2 Blue Neutral 3 Brown Live IMPORTANT The wire which is coloured Green Yellow must be connected to the terminal which is marked with the letter E or by the Earth symbol WARNING...

Страница 21: ...appliance has been converted to LPG then the bypass screw will HAVE to be screwed in until a small stable flame results Please ensure the supply pressure has been checked PRIOR to any adjustment Figu...

Страница 22: ...User Manual 22 Attach your receipt to this page...

Страница 23: ...please record details of your purchase below and staple your receipt on the opposite page Your serial number can be found on the rating plate of your Cooktop STORE DETAILS STORE NAME ADDRESS TELEPHONE...

Страница 24: ...as the same meaning referred to in the ACL and includes a situation when an Appliance cannot be repaired or it is uneconomic for Residentia Group at its discretion to repair an Appliance during the Wa...

Страница 25: ...ces come with a guarantee by Residentia Group that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any oth...

Страница 26: ...ner s handbook e defects caused by normal wear and tear accident negligence alteration misuse or incorrect installations f a product dismantled repaired or serviced by any serviceman other than an aut...

Страница 27: ...esatto house 27 This page is intentionally blank But if you want to draw something make notes or even write a recipe it s all yours...

Страница 28: ...A RESIDENTIA GROUP INITIATIVE everything you need...

Отзывы: