Tab. 1:  REGISTRI DELLE MISURE / 

REGISTERS OF MEASURED VALUES 

 

Register 

Type 

Read / Write 

Label 

Description 

Aron 

Unit 

100-101 

Float 

Read only 

V1 

Tensione fase 1 / 

Voltage Phase 1

 

 

102-103 

Float 

Read only 

I1 

Corrente fase 1 /

 Current Phase 1

 

 

104-105 

Float 

Read only 

P1 

Potenza attiva fase 1 / 

Active power Phase 1

 

 

106-107 

Float 

Read only 

Q1 

Potenza reattiva fase 1 / 

Reactive power Phase 1

 

 

VAR 

108-109 

Float 

Read only 

V12 

Tensione concatenata fase 1-2 / 

Linked Voltage Phase 1-2

 

 

110-111 

Float 

Read only 

V1pk 

Valore picco V1 nell’ultimo periodo AC / 

V1 peak value in last AC period

 

 

112-113 

Float 

Read only 

IP1pk 

Valore picco I1 nell’ultimo periodo AC / 

I1 peak value in last AC period

 

 

114-115 

Float 

Read only 

S1 

Potenza Apparente fase 1 / 

Apparent power Phase 1

 

 

VA 

116-117 

Float 

Read only 

PF1 

Fattore di potenza fase 1 / 

Power factor Phase 1

 

 

 

118-119 

Float 

Read only 

THD V1 

Distorsione armonica totale V1 / 

Total harmonic distortion V1

 

 

120-121 

Float 

Read only 

THD I1 

Distorsione armonica totale I1 / 

Total harmonic distortion I1

 

 

122-123 

Float 

Read only 

V2 

Tensione fase 2 / 

Voltage Phase 2

 

 

124-125 

Float 

Read only 

I2 

Corrente fase 2 /

 Current Phase 2

 

 

126-127 

Float 

Read only 

P2 

Potenza attiva fase 2 / 

Active power Phase 2

 

 

128-129 

Float 

Read only 

Q2 

Potenza reattiva fase 2 / 

Reactive power Phase 2

 

 

VAR 

130-131 

Float 

Read only 

V23 

Tensione concatenata fase 2-3 / 

Linked Voltage Phase 2-3

 

 

132-133 

Float 

Read only 

V2pk 

Valore picco V2 nell’ultimo periodo AC / 

V2 peak value in last AC period

 

 

134-135 

Float 

Read only 

I2pk 

Valore picco I2 nell’ultimo periodo AC / 

I2 peak value in last AC period

 

 

136-137 

Float 

Read only 

S2 

Potenza Apparente fase 2 / 

Apparent power Phase 2

 

 

VA 

138-139 

Float 

Read only 

PF2 

Fattore di potenza fase 2 / 

Power factor Phase 2

 

 

 

140-141 

Float 

Read only 

THD V2 

Distorsione armonica totale V2 / 

Total harmonic distortion V2

 

 

142-143 

Float 

Read only 

THD I2 

Distorsione armonica totale I2 / 

Total harmonic distortion I2

 

 

144-145 

Float 

Read only 

V3 

Tensione fase 3 / 

Voltage Phase 3

 

 

146-147 

Float 

Read only 

I3 

Corrente fase 3 /

 Current Phase 3

 

 

148-149 

Float 

Read only 

P3 

Potenza attiva fase 3 / 

Active power Phase 3

 

 

150-151 

Float 

Read only 

Q3 

Potenza reattiva fase 3 / 

Reactive power Phase 3

 

 

VAR 

152-153 

Float 

Read only 

V31 

Tensione concatenata fase 3-1 / 

Linked Voltage Phase 3-1

 

 

154-155 

Float 

Read only 

V3pk 

Valore picco V3 nell’ultimo periodo AC / 

V3 peak value in last AC period

 

 

156-157 

Float 

Read only 

I3pk 

Valore picco I3 nell’ultimo periodo AC / 

I3 peak value in last AC period

 

 

158-159 

Float 

Read only 

S3 

Potenza Apparente fase 2 / 

Apparent power Phase 2

 

 

VA 

160-161 

Float 

Read only 

PF3 

Fattore di potenza fase 3 / 

Power factor Phase 3

 

 

 

162-163 

Float 

Read only 

THD V3 

Distorsione armonica totale V3 / 

Total harmonic distortion V3

 

 

164-165 

Float 

Read only 

THD I3 

Distorsione armonica totale I3 / 

Total harmonic distortion I3

 

 

166-167 

Float 

Read only 

Freq 

Frequenza / 

Frequency

 

 

Hz 

168-169 

Float 

Read only 

Vtm 

Tensione concatenata media / 

Average Voltage  

(V12+V23+V31)/3 

 

170-171 

Float 

Read only 

Itm 

Corrente media / 

Average Current  

(I1+I2+I3)/3 

 

172-173 

Float 

Read only 

Ptot 

Potenza Attiva totale / 

Total Active power 

 (P1+P2+P3) 

 

174-175 

Float 

Read only 

Qtot 

Potenza Reattiva totale / 

Total Reactive power 

 (Q1+Q2+Q3) 

 

VAR 

176-177 

Float 

Read only 

Stot 

Potenza Apparente totale / 

Total Apparent power  

(

P²+Q²) 

 

VA 

178-179 

Float 

Read only 

PF 

Fattore di potenza del sistema trifase / 

The three-phase power factor

 

 

Φ 

180-181 

Float 

Read only 

INEU 

Corrente di neutro / 

Neutral current

 

 

199 

Int 

Read only 

 

Senso ciclico delle fasi (vedi Tab. 4) / 

Phase sequence (see Tab. 4)

 

 

 

200-201 

Float 

Read only 

EAP 

Energia attiva positiva / 

Positive Active Energy

 

 

Wh 

202-203 

Float 

Read only 

EAN 

Energia attiva negativa / 

Negaitive Active Energy

 

 

Wh 

204-205 

Float 

Read only 

ERP 

Energia reattiva positiva / 

Positive Reactive Energy

 

 

VARh 

206-207 

Float 

Read only 

ERN 

Energia reattiva negativa / Nega

tive Reactive Energy

 

 

VARh 

208-209 

Float 

Read only 

EAP1 

Energia attiva positiva fase 1 / 

Phase 1 Positive Active Energy

 

 

Wh 

210-211 

Float 

Read only 

EAN1 

Energia attiva negativa fase 1 / 

Phase 1 Negative Active Energy

 

 

Wh 

212-213 

Float 

Read only 

ERP1 

Energia reattiva positiva fase 1 / 

Phase 1 Positive Reactive Energy

 

 

VARh 

214-215 

Float 

Read only 

ERN1 

Energia reattiva negativa fase 1 / 

Phase 1 Negative Reactive Energy

 

 

VARh 

216-217 

Float 

Read only 

EAP2 

Energia attiva positiva fase 2 / 

Phase 2 Positive Active Energy

 

 

Wh 

218-219 

Float 

Read only 

EAN2 

Energia attiva negativa fase 2 / 

Phase 2 Negative Active Energy

 

 

Wh 

220-221 

Float 

Read only 

ERP2 

Energia reattiva positiva fase 2 / 

Phase 2 Positive Reactive Energy

 

 

VARh 

222-223 

Float 

Read only 

ERN2 

Energia reattiva negativa fase 2 / 

Phase 2 Negative Reactive Energy

 

 

VARh 

224-225 

Float 

Read only 

EAP3 

Energia attiva positiva fase 3 / 

Phase 3 Positive Active Energy

 

 

Wh 

226-227 

Float 

Read only 

EAN3 

Energia attiva negativa fase 3 / 

Phase 3 Negative Active Energy

 

 

Wh 

228-229 

Float 

Read only 

ERP3 

Energia reattiva positiva fase 3 / 

Phase 3 Positive Reactive Energy

 

 

VARh 

230-231 

Float 

Read only 

ERN3 

Energia reattiva negativa fase 3 / 

Phase 3 Negative Reactive Energy

 

 

VARh 

232-233 

Float 

Read only 

PMP 

Potenza attiva positiva media / 

Average Positive Active Power

 

 

 

Содержание E1200

Страница 1: ...ccia Ethernet configurazione dello strumento e visualizzazione misure da browser Web acquisizione dati da sistemi Scada con protocollo Modbus TCP inserzione trifase con 3 TA o 2 TA ARON o monofase con 1 TA rapporti TA e TV configurabili montaggio su profilato DIN EN50022 35 The Network analyzer E1200 entirely designed and developed by ESAM is built to comply with all the modern requirements of mea...

Страница 2: ...attiva uscente Active Energy Out Ea Ea1 Ea2 Ea3 Wh Energia reattiva entrante Reactive Energy In Er Er1 Er2 Er3 VARh Energia reattiva uscente Reactive Energy Out Er Er1 Er2 Er3 VARh Potenza attiva media entrante ultimi 15 minuti Average Active Power In last 15 minutes Pm Pm1 Pm2 Pm3 W Potenza attiva media uscente ultimi 15 minuti Average Active Power Out last 15 minutes Pm Pm1 Pm2 Pm3 W Potenza rea...

Страница 3: ...hase input voltage range 0 1 2Vn nominal input current 5A input current range 0 1 2 In continuous overload 1 5Vn 2In instantaneous overload 1 sec 2Vn 20In programmable external TV ratio 1 99999 programmable external TV ratio 1 99999 averaging time interval AC period 1 sec accuracy voltage current active power 0 2 of reading 5 100 of input range 45 65 Hz temperature coefficient 0 01 C RS485 serial ...

Страница 4: ...ia di rete Ethernet a 10 Mbit s in reti miste 10 100 1000 Mbit s ciò non costituisce un problema purché l E1200 venga collegato a uno switch di rete Evitare invece di usare uno hub in quanto ciò rallenterebbe anche i dispositivi in grado di comunicare fra di loro a velocità maggiore Lo strumento è dotato di un connettore di rete standard RJ45 e ha la seguente configurazione di default Indirizzo IP...

Страница 5: ...legare l E1200 a uno switch di rete con un cavo normale se l E1200 è stato correttamente configurato a questo punto sarà accessibile con un browser da qualsiasi PC collegato alla rete Lo strumento è completamente configurabile per mezzo del web server Il web server consente inoltre la visualizzazione di tutti i valori misurati e calcolati The E1200 network analyzer does not support DHCP and theref...

Страница 6: ...put modules V mA Outputs For each E3000 analog output max 4 E3000 modules 12 analog outputs Output type 0 10V 4 20mA Normal inverted output e g 4 20 or 20 4 mA Output function for power factor readings Low range of output variable High range of output variable Reset readings Individual commands allow to reset Max average power values Min max values of all the readings Energy values SERVER MODBUS T...

Страница 7: ...pronti a ricevere quando l E1200 inizia a rispondere SWFP ordine di trasmissione delle due word dei valori floating point valori validi 0 1 vedi protocollo Modbus nota 2 Parametro configurabile solo per la seconda porta seriale PROT selezione Modbus slave PROT 2 default oppure Modbus master PROT 4 per pilotaggio moduli di output analogico E3000 Impostazioni default di fabbrica per entrambe le port...

Страница 8: ...23 bits SWFP Command Setting to 0 word A will be sent before word B setting 1 word B will be sent before word A Modbus RTU implemented exception codes 1 illegal function invalid or non implemented function 2 illegal data address read or write request at an invalid address Ex Non existent register read one word only of a floating point value 3 illegal data value write request of an invalid value e ...

Страница 9: ... picco I3 nell ultimo periodo AC I3 peak value in last AC period A 158 159 Float Read only S3 Potenza Apparente fase 2 Apparent power Phase 2 VA 160 161 Float Read only PF3 Fattore di potenza fase 3 Power factor Phase 3 162 163 Float Read only THD V3 Distorsione armonica totale V3 Total harmonic distortion V3 164 165 Float Read only THD I3 Distorsione armonica totale I3 Total harmonic distortion I...

Страница 10: ...Phase 2 Average Neg Act Power W 284 285 Float Read only QMMP2 Max Potenza reatt pos media fase 2 Max Phase 2 Average Pos React Power VAR 286 287 Float Read only QMMN2 Max Potenza reatt neg media fase 2 Max Phase 2 Average Neg React Power VAR 288 289 Float Read only PMMP3 Max Potenza att pos media fase 3 Max Phase 3 Average Pos Act Power W 290 291 Float Read only PMMN3 Max Potenza att neg media fas...

Страница 11: ... potenza del sistema trifase The three phase power factor 2280 2281 2480 2481 Float Read only Corrente di neutro Neutral current A Tab 3 REGISTRI DEI PARAMETRI PARAMETER REGISTERS Register Type Read Write Label Description Value Unit 300 301 Float Read only TAP Ingresso nominale I Rated I Input A 302 303 Float Read only TVP Ingresso nominale V Rated V Input V 304 305 Float Read Write ETAR Rapporto...

Страница 12: ...ll uscita function applied to output Tab 8 2708 Int Read Write AOS13 E3000 mod 1 out 3 selezione misura in uscita output reading selection 6 100 180 2709 Int Read Write AOT13 E3000 mod 1 out 3 tipo di uscita output type Tab 7 2710 Int Read Write AOI13 E3000 mod 1 out 3 uscita normale invertita normal inverted output 0 1 2711 Int Read Write AOF13 E3000 mod 1 out 3 funzione applicata all uscita func...

Страница 13: ... 2 out 2 fine campo misura output high range 7 2820 2821 float Read Write AOL23 E3000 mod 2 out 3 inizio campo uscita output low range 7 2822 2823 float Read Write AOH23 E3000 mod 2 out 3 fine campo misura output high range 7 2824 2825 float Read Write AOL31 E3000 mod 3 out 1 inizio campo uscita output low range 7 2826 2827 float Read Write AOH31 E3000 mod 3 out 1 fine campo misura output high ran...

Страница 14: ... which word has to be sent first so set this parameter to have them sent in the order that your master Modbus equipment understands MSB LSB seeeeeee emmmmmmm mmmmmmmm mmmmmmmm word A word B s segno del numero 1 se il valore è negativo 0 se il valore è positivo Sign bit negative it is 1 positive it is 0 e esponente a 8 bit 8 bit exponent m mantissa del numero 23 bit The mantissa which is code in 23...

Страница 15: ... campo verificare che la rete RS485 sia cablata a regola d arte soprattutto per collegamenti di lunghezza elevata e con molti slave connessi usare doppino schermato di buona qualità collegare la calza al terminale 0 degli slave mettere la calza a terra in un unico punto evitare diramazioni della linea e collegamenti a stella montare la resistenza di terminazione 120 ohm ai due estremi della linea ...

Страница 16: ...ve cable too long or wrong type defective network switch 2 Check if the web server works otherwise verify the E1200 network configuration IP address netmask as detailed in the Ethernet interface section of this manual The E1200 IP address must be different from any already assigned static IP address and out of the range of dynamic IP addresses managed by DHCP 3 Check if the E1200 and your Modbus T...

Отзывы: