background image

-- 4 --

OF30e

DECLARATION OF CONFORMITY

ESAB Welding Equipment AB, S--695 81 Laxå, Sweden, declares that Wire feed unit Origo

TM

Feed

30w from serial number 638 onwards, conforms to standard EN 60974--5, in accordance with the re-

quirements of directive (73/23/EEC) and appendix (93/68/EEC) and standard EN 60974--10 in accord-

ance with the requirements of directive (89/336/EEC) and appendix (93/68/EEC).

--------------------------------------------------------------------------------------------------------------------------------------

Kent Eimbrodt

Global Director Equipment and Automation

ESAB AB

695 81 LAXÅ

SWEDEN

Tel: + 46 584 81000

Fax: + 46 584 411924

Laxå 2007--04--23

1

SAFETY

Users of ESAB welding equipment have the ultimate responsibility for ensuring that anyone who

works on or near the equipment observes all the relevant safety precautions. Safety precautions

must meet the requirements that apply to this type of welding equipment. The following recommen-

dations should be observed in addition to the standard regulations that apply to the workplace.

All work must be carried out by trained personnel well--acquainted with the operation of the welding

equipment. Incorrect operation of the equipment may lead to hazardous situations which can result

in injury to the operator and damage to the equipment.
1.

Anyone who uses the welding equipment must be familiar with:

S

its operation

S

location of emergency stops

S

its function

S

relevant safety precautions

S

welding

2.

The operator must ensure that:

S

no unauthorised person is stationed within the working area of the equipment when it is

started up.

S

no--one is unprotected when the arc is struck

3.

The workplace must:

S

be suitable for the purpose

S

be free from draughts

4.

Personal safety equipment

S

Always wear recommended personal safety equipment, such as safety glasses, flame--proof

clothing, safety gloves.

S

Do not wear loose--fitting items, such as scarves, bracelets, rings, etc., which could become

trapped or cause burns.

5.

General precautions

S

Make sure the return cable is connected securely.

S

Work on high voltage equipment

may only be carried out by a qualified electrician.

S

Appropriate fire extinquishing equipment must be clearly marked and close at hand.

S

Lubrication and maintenance must

not

be carried out on the equipment during operation.

GB

Содержание Origo Feed 30

Страница 1: ...Valid for serial no 638 0349 301 132 070426 Feed 30 Feed 30w Origo Instruction manual...

Страница 2: ...nection and control devices 8 5 2 Function explanation 10 5 3 Wire feed pressure 11 5 4 Changing loading wire 11 5 5 Flux cored wires welding 11 5 6 Aluminium wire welding 12 6 MAINTENANCE 12 6 1 Insp...

Страница 3: ...3 document...

Страница 4: ...operation of the welding equipment Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipment 1 Anyone who uses the we...

Страница 5: ...uitable screens or curtains FIRE HAZARD S Sparks spatter can cause fire Make sure therefore that there are no inflammable materials nearby NOISE Excessive noise can damage hearing S Protect your ears...

Страница 6: ...mension range 0 8 1 6 Fe SS 1 0 1 6 Al 1 0 1 6 FCW Shielding gas All types for MIG MAG max 5 bar Max diam weight of wire bobin 300 mm 18kg Dimensions lxwxh 700x255x420 Weight 14 8 kg Feed 30 with cool...

Страница 7: ...ectors turning aside an arm of the pump switch ELP Hoses and appropriate connectors are marked in red and blue d Install the bobbin with electrode wire e Input the wire between the rolls and further t...

Страница 8: ...ting parts can cause injury take great care To prevent the reel sliding off the hub Lock the reel in place by turning the red knob as shown on the warning label attached next to the hub WARNING When m...

Страница 9: ...9 OF30e GB...

Страница 10: ...switch released cut off the gas 5 2 3 Burnback time Burnback time is a delay between the time when the wire starts to brake until the time when the power source switches off the welding voltage Too sh...

Страница 11: ...n approx 50 mm from the piece of wood the wire should be fed out and bend fig 2 5 4 Changing loading wire S Open the side panel S Disconnect the pressure sensor by folding it backwards the pressure ro...

Страница 12: ...the customer himself attempts any work in the product during the guarantee period in order to rectify any faults 6 1 Inspection and cleaning Wire feed unit Check regularly that the wire feed unit is n...

Страница 13: ...Check whether the thermal overload trip has operated indicated by the orange lamp on the power source S Check the main power supply fuses Poor welding performance S Check that the welding current sup...

Страница 14: ...Diagram 14 dOF30 OrigoTM Feed 30w...

Страница 15: ...OrigoTM Feed 30 Feed 30w Edition 070426 15 oOF302 Valid for serial no 638 XXX XXXX Ordering numbers 0349 304 839 OrigoTM Feed 30w 42V 1 50 60Hz 0349 304 840 OrigoTM Feed 30 42V 1 50 60Hz...

Страница 16: ...9 484 355 C Drive gear 0349 484 356 D Pressure roller 0349 484 346 Fe Ss cored wire Al E Inlet nozzle 0349 308 000 Fe Ss cored wire Al F Intermediate nozzle 0349 484 344 Fe Ss cored wire Al G Outlet n...

Страница 17: ...OrigoTM Feed 30 Feed 30w Edition070426 17 wOF302...

Страница 18: ...OrigoTM Feed 30 Feed 30w Edition 070426 Accessories 18 aOF302 Traction kit 100 wheels set 0349 493 925 Traction kit 120 wheels set 0349 493 903...

Страница 19: ...92 22 ESAB international AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires...

Отзывы: