5.2

Function explanation

5.2.1

2--stroke mode

Set the 2--stroke mode by means of the knob (3). Set required wire speed by means

of the knob (2). The creep speed option can be set by means of the knob (6). If

creep speed is chosen the wire speed before the actual start of welding is reduced

by two. The creep speed is not recommended for speed setting close to the minimal.

The burn--back time should set by means of the knob (4). This setting should be

chosen experimentally, starting from the lowest values.

Pressing the torch switch opens the gas valve and then switching the power source

on and feeding the wire. Releasing the torch switch stops the wire feeding. After

delay proportional to burn--back time setting the power is switched off. Eventually

the gas is cut off too.

5.2.2

4--stroke mode

Set the 4--stroke mode by means of the knob (3). Other settings as for 2--stroke

mode.

This mode could be described as follows:

1. switch pressed -- gas starts to flow,
2. switch released -- power source is switched and wire is fed, the actual start of

welding,

3. switched pressed again -- stop of welding, gas remains flowing,
4. switch released -- cut off the gas.

5.2.3

Burnback time

Burnback time is a delay between the time when the wire starts to brake until the

time when the power source switches off the welding voltage. Too short burnback

time results in a long wire stickout after completion of welding, with a risk of the wire

being caught in the weld pool. Too long a burnback time results in a shorter stickout,

with increased risk of the arc striking back to the contact tip.

5.2.4

Creep start

Creep start means that the wire is fed at reduced speed within 1 sec after welding

torch trigger is pressed, and then the speed increases to the set speed.

5.2.5

Inching and gas purge modes

Set the required mode by means of the knob (3). Inching or gas purge is started by

means of the torch switch.

5.2.6

Wire feed speed

This sets the required feed speed of the filler wire in m/minute.

5.2.7

Spot welding

Set the spot welding mode by means of the knob (3). Set the required time of the

spot welding by means of the knob (5). Other settings as for previously described

modes. The control sequence is similar to 2--stroke mode sequence. The difference

is that the welding is stopped automatically after particular time. The torch switch

must be pressed up to the end of welding. Releasing the torch switch enables the

next spot welding cycle.

GB

Содержание Origo Feed 30

Страница 1: ...Valid for serial no 638 0349 301 132 070426 Feed 30 Feed 30w Origo Instruction manual...

Страница 2: ...nection and control devices 8 5 2 Function explanation 10 5 3 Wire feed pressure 11 5 4 Changing loading wire 11 5 5 Flux cored wires welding 11 5 6 Aluminium wire welding 12 6 MAINTENANCE 12 6 1 Insp...

Страница 3: ...3 document...

Страница 4: ...operation of the welding equipment Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipment 1 Anyone who uses the we...

Страница 5: ...uitable screens or curtains FIRE HAZARD S Sparks spatter can cause fire Make sure therefore that there are no inflammable materials nearby NOISE Excessive noise can damage hearing S Protect your ears...

Страница 6: ...mension range 0 8 1 6 Fe SS 1 0 1 6 Al 1 0 1 6 FCW Shielding gas All types for MIG MAG max 5 bar Max diam weight of wire bobin 300 mm 18kg Dimensions lxwxh 700x255x420 Weight 14 8 kg Feed 30 with cool...

Страница 7: ...ectors turning aside an arm of the pump switch ELP Hoses and appropriate connectors are marked in red and blue d Install the bobbin with electrode wire e Input the wire between the rolls and further t...

Страница 8: ...ting parts can cause injury take great care To prevent the reel sliding off the hub Lock the reel in place by turning the red knob as shown on the warning label attached next to the hub WARNING When m...

Страница 9: ...9 OF30e GB...

Страница 10: ...switch released cut off the gas 5 2 3 Burnback time Burnback time is a delay between the time when the wire starts to brake until the time when the power source switches off the welding voltage Too sh...

Страница 11: ...n approx 50 mm from the piece of wood the wire should be fed out and bend fig 2 5 4 Changing loading wire S Open the side panel S Disconnect the pressure sensor by folding it backwards the pressure ro...

Страница 12: ...the customer himself attempts any work in the product during the guarantee period in order to rectify any faults 6 1 Inspection and cleaning Wire feed unit Check regularly that the wire feed unit is n...

Страница 13: ...Check whether the thermal overload trip has operated indicated by the orange lamp on the power source S Check the main power supply fuses Poor welding performance S Check that the welding current sup...

Страница 14: ...Diagram 14 dOF30 OrigoTM Feed 30w...

Страница 15: ...OrigoTM Feed 30 Feed 30w Edition 070426 15 oOF302 Valid for serial no 638 XXX XXXX Ordering numbers 0349 304 839 OrigoTM Feed 30w 42V 1 50 60Hz 0349 304 840 OrigoTM Feed 30 42V 1 50 60Hz...

Страница 16: ...9 484 355 C Drive gear 0349 484 356 D Pressure roller 0349 484 346 Fe Ss cored wire Al E Inlet nozzle 0349 308 000 Fe Ss cored wire Al F Intermediate nozzle 0349 484 344 Fe Ss cored wire Al G Outlet n...

Страница 17: ...OrigoTM Feed 30 Feed 30w Edition070426 17 wOF302...

Страница 18: ...OrigoTM Feed 30 Feed 30w Edition 070426 Accessories 18 aOF302 Traction kit 100 wheels set 0349 493 925 Traction kit 120 wheels set 0349 493 903...

Страница 19: ...92 22 ESAB international AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires...

Отзывы: