ESAB FABRICATOR 252i
BASIC WELDING 4-20 Manual 0-5423
FAULT
CAUSE
REMEDY
7 Dirty weld pool
A Electrode contaminated
by contact with work
piece or filler rod
material.
A Clean the electrode by grinding off the
contaminates.
B Work piece surface has
foreign material on it.
B Clean surface.
C Gas contaminated with
air.
C Check gas lines for cuts and loose fitting
or change gas cylinder.
8 Poor weld finish
Inadequate shielding
gas.
Increase gas flow or check gas line for
gas flow problems.
9 Arc start is not smooth.
A Tungsten electrode
is too large for the
welding current.
A Select the right size electrode. Refer to
Table 4-6 ESAB Electrode Selection Chart.
B The wrong electrode
is being used for the
welding job.
B Select the right electrode type. Refer to
Table 4-8 ESAB Electrode Selection Chart.
C Gas flow rate is too
high.
C Select the right rate for the welding job.
Refer to Table 4-10.
D Incorrect shielding gas
is being used.
D Select the right shielding gas.
E Poor work clamp
connection to work
piece.
E Improve connection to work piece.
10 Arc flutters during TIG
welding.
Tungsten electrode
is too large for the
welding current.
Select the right size electrode. Refer to
Table 4-6 ESAB Electrode Selection Chart.
Table 4-10: TIG (GTAW) Welding Problems