5 OPERATION
0463 618 001
- 45 -
© ESAB AB 2019
1.
Install the two new drive rollers (both the same part number and in the same and
correct grove orientation). Verify that the correct size groove is oriented on the
inside
(see Figure 17).
NOTE!
The wire-feed rollers will either be replaced (to correspond with the size and
type of the new wire being installed) or reused if the same size and type of
wire is being replaced.
Figure 17. Wire-feed rollers offered in multiple sizes
1.
Labels
NOTE!
Label on roller-side matches with the groove on the opposite-side of the roller.
2.
Tighten the drive-roller retaining screw by turning it in the clockwise direction.
Hand-tight is sufficient.
3.
The wire must be installed through the wire-feed assembly (see "Installing wire"
subsection).
NOTE!
If the wire was removed the wire will have to be re-installed (see "Installing
wire" subsection).
4.
Close the pressure rollers on the wire.
5.
Adjust the wire-feed pressure by adjusting the tension on the wire at the wire-feed
rollers by turning the tension knob using the procedure in "Setting wire-feed pressure"
section.
6.
Close the cover on the wire-bobbin side of the EMP unit.
Содержание EMP 285ic 1ph
Страница 27: ...5 OPERATION 0463 618 001 27 ESAB AB 2019 5 5 1 2 SMAW Stick 230 V 1ph 5 5 1 3 GMAW MIG 120 V 1ph ...
Страница 28: ...5 OPERATION 0463 618 001 28 ESAB AB 2019 5 5 1 4 GMAW MIG 230 V 1ph 5 5 1 5 GTAW TIG 120 V 1ph ...
Страница 77: ...ROLLER WIRE GUIDE SELECTION 0463 618 001 77 ESAB AB 2019 ...