5 OPERATION
0463 618 001
- 40 -
© ESAB AB 2019
5.10
Setting wire-feed pressure
NOTE!
This procedure requires the unit be powered ON. The gas does not need to be
connected for this procedure.
1.
Turn power to the unit ON.
2.
Start by making sure that the wire moves smoothly through the wire guide.
CAUTION!
It is important that the feed-pressure is not too high or too low.
3.
Check that the feed-pressure is set correctly, feed out the wire against an insulated
object, e.g. a piece of wood.
4.
Adjusting for minimum roller pressure:
When you hold the welding torch approximately ¼ in. (6 mm) from the piece of wood
(see Figure 11), the wire-feed rollers should slip. If they don’t, reduce the tension on
the wire by adjusting the tension knob on the wire-feed assembly.
Figure 11. Check feed-roller for slip, indicating no over-pressure
5.
Adjusting for correct roller pressure:
If you hold the welding torch approximately 2 in. (50 mm) from the piece of wood, the
wire should be fed out and bend (Figure 12).
Figure 12. Checking for proper feed-roller pressure
5.11
Removing/installing wire-feed rollers
WARNING!
Power should be turned off for this procedure.
NOTE!
Gas does not need to be connected for this procedure.