
5 OPERATION
0463 618 001
- 38 -
© ESAB AB 2019
5.
If wire remains in the torch assembly:
Disconnect the torch assembly from the EMP unit by loosening the torch connector
holding knob and disconnecting the torch connector (see Figure 10).
Figure 10. Holding knob for torch adapter
1.
Torch-connector holding knob
6.
Pull the remaining length of the wire through the wire-feed assembly and, with the
torch, set the torch assembly aside (with the loose wire still installed in the torch). The
old wire should now be completely removed from the wire-feed assembly.
7.
Remove the bobbin from the unit (see “Removing/installing bobbin” section).
8.
If wire remains in the torch assembly:
Pull the length of old wire out of the torch assembly from either end of the torch
assembly.
5.8.2
Installing wire
CAUTION!
Too long a torch liner risks damage to the wire-feed assembly if forced to fit when
attempting to connect the torch to the power unit.
Refer to the torch manual for instructions for torch liner replacement.
Содержание EMP 285ic 1ph
Страница 27: ...5 OPERATION 0463 618 001 27 ESAB AB 2019 5 5 1 2 SMAW Stick 230 V 1ph 5 5 1 3 GMAW MIG 120 V 1ph ...
Страница 28: ...5 OPERATION 0463 618 001 28 ESAB AB 2019 5 5 1 4 GMAW MIG 230 V 1ph 5 5 1 5 GTAW TIG 120 V 1ph ...
Страница 77: ...ROLLER WIRE GUIDE SELECTION 0463 618 001 77 ESAB AB 2019 ...