14
– Failures analysis
14
– 1 – Start up failure
14
– 1 – A – Compressor does not start
Source of errors
Solution
No power supply
Check voltage
Coupling broken
Replace
Piston jams
Replace piston and fill with oil level
14
– 2 – Running failure
14
– 2 – A – Compressor start but trips
Source of errors
Solution
Airing broken
Replace decompression device
Loose cable
Check the wiring
14
– 2 – B – Compressor runs but there is no delivery pressure
Source of errors
Solution
Broken piston
Replace
Broken output valve
Replace
14
– 2 – C – Compressor overheat
Source of errors
Solution
Clogged non return valve
Replace
Clogged output valve
Replace
Worn piston rings
Replace
No oil
Fill with oil