Led lit
1°
2°
3°
4°
5°
6°
7°
8°
Green led weight
1
2
4
8
16
32
64
128
Red led weight
0
0
0
0
0
0
0
0
T H E S M A R T L I V I N G
8E ) Relay release time programming
The release time after which the relay programmed as delayed releases is programmable.
The value of the time can be introduced making use of the buttons P1 and P2. Through 8 pressures on P1 and P2, to
which correspond as many lightings of the leds DL1(Red) and DL2 (Green), it is possible to introduce a number in
binary coding that gives the value of the delay.
Procedure:
- Press for 4 sec. the button corresponding to the relay to which you want to modify the delay time;
The configuration led lights on; subsequently press P3: the leds lit will turn off; after begin the sequence of 8 pressures
off P1 and P2 in base to the desired time and according to Tab.2. An acoustic signal points out the end of the
procedure
Push buttons
1°
2°
3°
4°
5°
6°
7°
8°
Seconds
1
2
4
8
16
32
P1
P1
Seconds
10
20
40
80
160
320
P2
P1
Minutes
2
4
8
16
32
64
P1
P2
Minutes
20
40
80
160
320
640
P2
P2
One pressure on P1 has weight 0 while one pressure on P2 has weight 1. So, once finished all the pressures
concerning to the chosen value, it isn’t necessary to effect the remaining pressures on P1
Example 1 = 8 sec. delay : introduce the sequence : P1 - P1 - P1 - P2 - P1 - P1 - P1 - P1.
Example 2 = 2 min. delay: introduce the sequence : P2 - P1 - P1 - P1 - P1 - P1 - P1 - P2.
8 - MEMORY MANAGEMENT
8A) - Transmitter memory position display
It is possible to display the memory position of the last received transmitter.
Procedure:
Activate the transmitter ; then press in sequence : the button P4 for 4 sec., P4 again for one instant and then P1. The receiver
begins a sequence of 8 lightings of DL1(red) and DL2 ( green), following pointed out for simplicity as LR and LV: referring to
that it is possible to find the memory position occupied by the code just received. The number pointed out by the sequence
of lightings is calculable by the following table:
Esempio:
Led lighting sequence:
LR, LV, LV, LV, LR, LR LR, LR
Result number: 0 +0 +4 +8 +0 +0 +0 +0 = 12
Then the transmitter occupies the 12th position of the memory.
8B) - Display of the programmed delay of each relay
It is possible to display the delay time planned on the relay programmed as delayed.
Procedure:
Press for 4 sec the button corresponding to the relay which has to be check; press then in sequence: P4 for 1 sec. and then
P3 for one instant. At this point a sequence of 8 lightings of the leds LD1 and LD2 commences: referring to that it is possible
to calculate the planned delay.
The number shown by the sequence is given by the Tab.2.
Pag. 17
Tab. 4
Tab. 3