N
1
2
L
0
3
4
12
6
24
SEL 2641 R433 V4
SEL 2641 R433 C4
8
9 10
12
11
7
6
13 14
RL1
RL2
RL3
RL4
15 16
F1
T H E S M A R T L I V I N G
Connections
1 - Power supply (fig.5)
ATTENTION: The connections differ
upon the type.
Mod. SEL 2641 R433 V4
Connect the Mains 230 Vac to the following terminals
(fig. 4):
terminal 1 = Neutral ( 230 Vac )
terminal 2 = Phase (230 Vac )
ATTENTION :
Connect the appliance to the
building electric plant throught
a magnetothermic switch with
minimum contact distance
of 3 mm.
Mod. SEL 2641 R433 C4
Connect the power supply 12/24 Vac/dc to the terminals
3,4,5.
terminal 3 = 0
terminal 4 = +12 Vac/dc
terminal 5 = +24 Vac/dc
2 -Fuse (fig. 6)
The fuse F1 of 315 mA it is used for the electronic card
protection.
3 - Relay outputs (fig. 7)
terminal 6 =
C relay1
terminal 7 =
NA relay1
terminal 8 =
C relay 2
terminal 9 =
NA relay2
terminal 10 = C relay 3
terminal 11 = NA relay 3
terminal 12 = C relay 4
terminal 13 = NA relay4
terminal 14 = NC relay4
4 -Antenna (fig. 8)
terminal 15 and the shield to the terminal 16; if you use a
piece of net ( 16,5 cm ) connect it to the terminal 15.
- if you connect an antenna ( not provided ) fix the net to the
Pag. 13
Fig. 6
Fig. 5
Fig. 7
Figura 8