8.4.1. Alarm output functions
Data sour ces of the alarms:
• Va lue of the en co der
• Ma xi mum va lue
• Mi ni mum va lue
• Hold va lue
In di ca ti on of alarms
• Two re lay out put
• LED 1 and LED 2 at the front
Pro gramma ble func ti ons of the alarms
• Alarm va lue
• Hy ste re sis
• Re lea se de lay time and ope ra te de lay time
• High or low alarm
Ma nu al alarm re set
In de pen dence of pro gram ming the di gi tal in puts and the func tio nal push but ton
is the alarm out put lat ched or not lat ched.
Alarm out put lat ched:
• If the di gi tal in put 1, 2 (pa ra me ter 0-11 and 0-12) or the func tio nal push but ton
(pa ra me ter 0-13) is pro gram med to ma nu al alarm re set
• Re set the lat ched alarm out put by ac ti va te the di gi tal in puts or press the func tio nal
push but ton
Alarm out put not lat ched:
• If the di gi tal in puts and the func tio nal push but ton
are not pro gram med to ma -
nu al alarm re set
Dis play and edit the alarm va lues
• In si de the pro gram mig rou ti ne, which is re ached over the en ter code. Du ring the
pro gram ming rou ti ne no mea su re ment is ta ken.
• Out si de the pro gram ming rou ti ne by pres sing the push but ton
or
du ring
nor mal mea su re ment are ta ken.
The edi ti on is end when pres sing the push but ton
. Ther fo re the alarm va lue
will be up to date.
ERMA-Electronic GmbH
23
8. Procedure of programming
P