6.
Commands of analog output level (P-03) (Only SSI 9001)
6.1.
Data source for analog output (Only SSI 9001)
Read the setting of data source for the analog output
SOH
D
D
STX
D
A
D
ETX
BCC
Answer of SSI 9001
STX
X
X
X
ETX
BCC
Set the data source of analog output
SOH
D
D
STX
D
A
D
X
X
X
ETX
BCC
X
setting number of data source for the analog output
valid values
000 to 003
Answer of SSI 9001
ACK
Example: Data source for analog output = 1 (MAX value)
SOH
D
D
STX
D
A
D
0
0
1
ETX
BCC
6.2.
Configuration of analog output (Only SSI 9001)
Read the setting of configuration for analog output
SOH
D
D
STX
D
A
C
ETX
BCC
Answer of SSI 9001
STX
X
X
X
ETX
BCC
Set the configuration of analog output
SOH
D
D
STX
D
A
C
X
X
X
ETX
BCC
X
setting number of configuration for the analog output
valid values
000 to 003
Answer of SSI 9001
ACK
Example: Configuration of analog output = 2 (0 to 20 mA)
SOH
D
D
STX
D
A
C
0
0
2
ETX
BCC