4.3.
Master/Slave Mode
Read the setting mode of the SSI 9001/2
SOH
D
D
STX
M
S
B
ETX
BCC
Answer of SSI 9001/2
STX
X
X
X
ETX
BCC
Set the mode
SOH
D
D
STX
M
S
B
X
X
X
ETX
BCC
X
setting mode of the SSI 9001/2
valid values
000 or 001
Answer of SSI 9001/2
ACK
Example: Slave-Mode
SOH
D
D
STX
M
S
B
0
0
1
ETX
BCC
4.4.
Clock for Master-Mode
Read the setting clock of SSI 9001/2
SOH
D
D
STX
C
L
K
ETX
BCC
Answer of SSI 9001/2
STX
X
X
X
ETX
BCC
Set the clock
SOH
D
D
STX
C
L
K
X
X
X
ETX
BCC
X
setting clock of SSI 9001/2
valid values
000 or 001
Answer of SSI 9001/2
ACK
Example: Clock = 200 kHz
SOH
D
D
STX
C
L
K
0
0
0
ETX
BCC
4. Commands of configuration level (P-00)