5.3.
Commands of alarm output 3 (Only SSI 9002)
5.3.1. Data source for alarm output 3 (Only SSI 9002)
Read the setting of data source for the alarm output 3
SOH
D
D
STX
G
3
D
ETX
BCC
Answer of SSI 9002
STX
X
X
X
ETX
BCC
Set the data source for the alarm output 3
SOH
D
D
STX
G
3
D
X
X
X
ETX
BCC
X
setting number of data source for the alarm output 2
valid values
000 to 004
Answer of SSI 9002
ACK
Example: Data source for alarm output 3 = 1 (Encoder value)
SOH
D
D
STX
G
3
D
0
0
1
ETX
BCC
5.3.2. Switching logic of alarm output 3 (Only SSI 9002)
Read the setting of switching logic for the alarm output 3
SOH
D
D
STX
G
3
C
ETX
BCC
Answer of SSI 9002
STX
X
X
X
ETX
BCC
Set the switching logic of alarm output 3
SOH
D
D
STX
G
3
C
X
X
X
ETX
BCC
X
setting number of switching logic for the alarm output 1
valid values
000 to 003
Answer of SSI 9002
ACK
Example: Switching logic of alarm output 3 = 1 (contact closed at high limit)
SOH
D
D
STX
G
3
C
0
0
1
ETX
BCC
5. Commands of alarm output level (P-02)