5.1.3. Alarm point of alarm output 1
Read the setting of alarm point for alarm output 1
SOH
D
D
STX
G
1
W
ETX
BCC
Answer of SSI 9001/2
STX
V or X
X
X
X
X
X
ETX
BCC
Set the alarm point of alarm output 1
SOH
D
D
STX
G
1
W
V or X
X
X
X
X
X
ETX
BCC
V
sign
positive: ‘ ‘ (ASCII 20h)
negative: ‘-’ (ASCII 2Dh)
X
alarm point
valid values
-99999 to 999999
Answer of SSI 9001/2
ACK
Example: Alarm point of alarm output 1 = 2500
SOH
D
D
STX
G
1
W
0
0
2
5
0
0
ETX
BCC
5.1.4. Hysteresis of alram output 1
Read the setting of hysteresis for the alarm output 1
SOH
D
D
STX
G
1
H
ETX
BCC
Answer of SSI 9001/2
STX
X
X
X
X
X
X
ETX
BCC
Set the hysteresis of alarm output 1
SOH
D
D
STX
G
1
H
0
0
X
X
X
X
ETX
BCC
X
hysteresis
valid values
000001 to 001000
Answer of SSI 9001/2
ACK
Example: Hysteresis of alarm output 1 = 100
SOH
D
D
STX
G
1
H
0
0
0
1
0
0
ETX
BCC