4.5.
Zero defination
Read the setting number of zero defination
SOH
D
D
STX
N
U
L
ETX
BCC
Answer of SSI 9001/2
STX
X
X
X
ETX
BCC
Set the zero defination of SSI 9001/2
SOH
D
D
STX
N
U
L
X
X
X
ETX
BCC
X
setting number of zero defination
valid values
000 or 001
Answer of SSI 9001/2
ACK
Example: Zero defination with ± display
SOH
D
D
STX
N
U
L
0
0
1
ETX
BCC
4.6.
Rotation direction
Read the setting number of rotation direction
SOH
D
D
STX
D
I
R
ETX
BCC
Answer of SSI 9001/2
STX
X
X
X
ETX
BCC
Set the rotation direction
SOH
D
D
STX
D
I
R
X
X
X
ETX
BCC
X
setting number of rotation direction
valid values
000 or 001
Answer of SSI 9001/2
ACK
Example: Rotation direction clockwise
SOH
D
D
STX
D
I
R
0
0
0
ETX
BCC
4. Commands of configuration level (P-00)