background image

6

Sump Cleaner Warranty 

(cont.)

Eriez HydroFlow shall not be liable for any damage  
to or loss of any cutting fluids or for loss of any income 
or profits due to the malfunctioning of the equipment 
hereinafter described, whether the malfunctioning is 
caused by defects in factory workmanship and/or  
faulty material, or any other cause whatsoever.
Component parts returned for replacement must 
show the original unit serial number from which 
they were removed. Parts returned without the 
aforementioned serial number will be replaced at 
established replacement prices. This warranty does 
not cover equipment damaged by misuse, negligence 
or accident. Vacuum and pressure relief valves are 
preset at the factory. ALTERATION OF THE SETTING 
EXCEPT WITH THE SPECIFIC AUTHORIZATION 
OF ERIEZ HydroFlow OR ITS AUTHORIZED 
REPRESENTATIVES WILL VOID THIS WARRANTY.

1.  Remove the cover of the basket. Keep hands and 

fingers from under the filter basket gasket. Take 
out the following items:

 

A.  Filter basket (factory assembled with sleeve)

 

B.  Discharge hose with nozzle

 

C.  Suction hose

 

D.  Cleaning tool

 

E.  Spare filter sleeve or filter bags

 

F.  LP bottle brackets (on LP models)

2.  Check the locking pin that holds the filter basket’s 

trapdoor shut. Make sure it is securely in place 
(fully extended as shown in the drawing at the  
end of the manual).

3.  Keeping hands and fingers from under the basket 

lip, reseat the filter basket in the tank. Replace the 
tank lid and clamp it down.

4.  Attach the suction hose to the intake connection 

on the tank lid. Attach the cleaning tool to this 
hose, then coil the hose around the push handle 
or hose hangers provided at the basket end of the 
tank. Place cleaning tool in pipe holder attached  
to the side of the tank.

5.  Couple the discharge hose to the discharge 

connection on the side of the tank and coil it over 
the push handle or hose hangers provided. Make 
sure the discharge nozzle assembly is installed  
on the other end of the hose.

6.  On LP models, remove the bolts from the side  

of the base plate and mount the bottle brackets  
on the plate using the bolts provided.

Assembly

Содержание FJ-310A

Страница 1: ...eaner 1 Installation Operation and Maintenance Instructions FJ 310A Sump cleaner ERIEZ MAGNETICS HEADQUARTERS 2200 ASBURY ROAD ERIE PA 16506 1402 U S A WORLD AUTHORITY IN SEPARATION TECHNOLOGIES P C 7...

Страница 2: ...E FEATURES 4 SUMP CLEANER WARRANTY 5 ASSEMBLY 6 OPERATING TIPS 7 LP MODELS 8 LP GAS DUAL TANK MODELS OPERATION 10 AIR OPERATED MODELS 11 AIR VENTURI DUAL TANK OPERATION 15 120V MODELS 13 120V DUAL TAN...

Страница 3: ...fter operating engine driven units LP gas or gasoline in the discharge mode and before stopping engine turn the SUCTION DISCHARGE lever to the SUCTION position The engine will SPEED UP momentarily and...

Страница 4: ...eak proof round cleanout doors are faster and easier to remove and replace than the oval internal manholes used by other manufacturers The thick pliable gasket bonded to the cleanout door virtually el...

Страница 5: ...turers for purpose of pursuing warranty claims or making service arrangements or any other purpose Copies of such third party sub assembly manufacturers specific warranty information will be shipped w...

Страница 6: ...ake out the following items A Filter basket factory assembled with sleeve B Discharge hose with nozzle C Suction hose D Cleaning tool E Spare filter sleeve or filter bags F LP bottle brackets on LP mo...

Страница 7: ...th water soluble coolants and another for use with cutting oils If you must use one unit for both the sump cleaner must be thoroughly cleaned when switching products If at all possible purchase a filt...

Страница 8: ...n Release key when the engine starts and move choke to the OFF position Figure 3 Pull out for CHOKE Figure 4 Turn key to START 5 Vacuum coolant and chips from the sump 6 As soon as fluid stops passing...

Страница 9: ...of fluid in the bottom of the compartment This is unimportant if the compartment is used for one type of coolant only If different coolants are involved remove the compartment s drain plug to empty it...

Страница 10: ...suction and discharge hoses to the proper fittings on that tank compartment Cap off all other fittings 5 For dirty fluid suction operation Activate the Pull out for CHOKE Turn key to START float swit...

Страница 11: ...d operation closed discharge open suction Failure to do so will allow particulate to enter the valve seat and seize the valve D As soon as fluid stops passing through the hose release pressure by shif...

Страница 12: ...mit switch bypasses the float switch needed to prevent overfilling during the suction operation but is not required for discharge operation The engine won t start in the discharge mode if sump cleaner...

Страница 13: ...eded Inspect tank for sludge buildup clean as needed Check blower oil level add SAE 40 non detergent oil as needed Grease blower use 2 bearing grease 500 hours Check engine air filter replace as neede...

Страница 14: ...uld be taken out of service immediately until the parts are repaired or replaced DO NOT eliminate the safety release valve or replace it with a release valve rated higher than 15 PSI DO NOT reset the...

Страница 15: ...tower during removal position the lifting power source e g crane directly over the center of the basket D Hoist the basket Keep hands and fingers clear If the basket is binding and unable to lift free...

Страница 16: ...harge nozzle D Attach the nozzle end of this hose to the clean coolant supply tank Turn on the compressed air and reattach the discharge nozzle to the hose when full Close vacuum valve V2 The compress...

Страница 17: ...ON position NOTE THE FLOAT SWITCH WILL ONLY WORK WHEN SUCTION ON IS SELECTED IT IS NOT WIRED INTO THE DISCHARGE ON CIRCUIT 3 Connect the Sump Cleaner to the electrical supply specified on the electri...

Страница 18: ...eposition the lifting device so that the basket exits the center of the tower E DO NOT TOUCH BASKET DURING REMOVAL F Position the basket over the waste receptacle G For 50 gallon units empty contents...

Страница 19: ...containing the motor assembly C Close valve S 1 D Attach the 1 1 2 hose to the clean coolant compartment inlet port and remove the discharge nozzle F Attach the nozzle end of this hose to the clean c...

Страница 20: ...cuit to drop out at a predetermined liquid level in the tank preventing overfilling and pump damage The discharge circuit has no such float switch therefore the sump cleaner must be plugged into outle...

Страница 21: ...center of the tower return lower basket to the sump cleaner tower Reposition the lifting device so that the basket exits the center of the tower E DO NOT TOUCH BASKET DURING REMOVAL F Position the bas...

Страница 22: ...valve V1 attach the 1 1 2 hose to the discharge port place the discharge nozzle in the machine sump push the DISCHARGE button and depress the discharge hose nozzle valve A Be sure the suction inlet ba...

Страница 23: ...ce Schedule 9 To discharge clean fluid to refill a machine sump close the suction inlet ball valve V1 attach the 1 1 2 hose to the discharge port place the discharge nozzle in the machine sump push th...

Страница 24: ...of the tank Remove these periodically by opening the drain plug and with the filter basket out of the sump cleaner flush the tank with a water hose 6 Periodically while the basket is out of the tank c...

Страница 25: ...Check for obstructions physically remove 2B Check for cracks or holes replace 3 Air leakage 3 Check all hose connections for tightness make sure female quick disconnect fittings have gaskets in place...

Страница 26: ...l coolant supplier for corrective action LP Engine Stalls During Discharge or Suction 1 Engine 1 Check engine RPM adjust as necessary 2 Regulator 2 Pressure or vacuum regulator could be out of adjustm...

Страница 27: ...Sump Cleaner 27...

Страница 28: ...0 345 4946 Fax 814 838 4960 International Fax 814 833 3348 Web Site http www eriez com e mail eriez eriez com Manufacturing Facilities AUSTRALIA BRAZIL CANADA CHINA INDIA JAPAN MEXICO SOUTH AFRICA UNI...

Отзывы: