R e a l - Ti m e   M P E G - 4   AV C   U l t r a c o m p r e s s i o n   ( S i n g l e - s l o t )
Transcoder

In addition to the dual-slot MPEG-4 AVC Ultracompression Transcoder 
described above, there is a single-slot MPEG-4 AVC Ultracompression Transcoder 
which fits in a single PMC slot. The advantages for a single-slot transcoder are:

Fits in a single slot, so 8 of them can be fitted in one iPlex chassis.

Improved video quality compared to the dual-slot encoder.

Up to 8 audio channels can be encoded by each card.

Содержание TANDBERG Television iPlex N20001

Страница 1: ...www tandbergtv com INSTALLATION AND HARDWARE SPECIFICATION GUIDE iPlex Software Version 5 0 iPlex 112 0113 02 Rev A...

Страница 2: ...less GoAhead otherwise instructs the year 2001 is to be replaced with the year during which the release of the Original Code containing the notice is issued by GoAhead If this year is not supplied wit...

Страница 3: ...Important Safety Information Please note the following 1 The TANDBERG Television iPlex is intended for indoor use only 2 In case of emergency disconnect the power cords 3 If power cords are not provid...

Страница 4: ...w density polyethylene LDPE materials Packaging Markings The symbols printed on the outer carton are described as follows Materials Declaration TANDBERG Television products are designed and manufactur...

Страница 5: ...N012040 MPEG 4 AVC SD UltraCompression Encoder SDI input HD upgradeable N012010 MPEG 4 AVC HD UltraCompression Encoder N012022 MPEG 2 4 AVC SD PIP Transcoder N012023 MPEG 2 4 AVC SD Transcoder N012041...

Страница 6: ...aking the hazardous materials TANDBERG Television expects the normal use environment to be in an equipment room at con trolled temperatures around 22 C with moderate humidity around 60 and clean air n...

Страница 7: ...sposal Recycling TANDBERG Television provides assistance to customers and recyclers through our web site Http www tandbergtv com productrecycling ink Please contact TANDBERG Television s cus tomer ser...

Страница 8: ...8...

Страница 9: ...rview 22 Install the iPlex Hardware 22 Set Up the iPlex Control Station 22 Configuration Using the Front Panel Controls 22 Configuration Using the Serial Port 22 Manage the iPlex Unit 22 Chapter 2 Har...

Страница 10: ...odules 52 Media Processor DSP 4PAC Submodule 52 DSP 6 PAC Transrating Submodule 53 MPEG 4 AVC Ultracompression Transcoder 53 MPEG 4 AVC Ultracompression Single slot Transcoder 55 Small Form Factor Plu...

Страница 11: ...tistics 85 Configuration 85 Configure an Existing ASI In Port as DVB 86 Creating Ports and Network Routing 86 Create Network Port 86 Creating a VLAN 87 Configuring an ASIOut 87 Appendix A Connecting i...

Страница 12: ...iPlex Installation and Hardware Specifications Guide 12...

Страница 13: ...13 Introducing TANDBERG Television iPlex Chapter 1...

Страница 14: ...e software Other iPlex Guides In addition to this guide you can also refer to the following guides Web Interface User Guide for information on Hardware specifications Basic concepts Web interface feat...

Страница 15: ...ing regular business hours see the Support Check List Contact Information Support Check List When contacting Customer Support please provide the following information Your name company name e mail add...

Страница 16: ...of the TANDBERG Television iPlex 1 RU Chassis based with 8 submodule slots for multiple video data interfaces Highest density chassis available today Routing of IP traffic Video encoding Delivery of M...

Страница 17: ...dule connectivity via the carrier card The carrier card provides a standards based mezzanine interface for up to four submodule cards per carrier card and up to two carrier cards per chassis thus up t...

Страница 18: ...r Supports Standard Definition uncompressed digital video inputs DSP 4PAC or Media Processor Uses four high speed DSPs to provide a wide range of functionality including MPEG 2 to MPEG 4 Advanced Tran...

Страница 19: ...following input inter faces unbalanced balanced AES or embedded Serial Digital Interface SDI The encoder supports analog and digital video sources For an analog video signal S Video or composite vide...

Страница 20: ...PEG 4 AVC Transcoding The Media DSP 4PAC Pro cessor Submodule uses four DSPs to give it the performance needed to meet these applications demands And because it is programmable the Media Processor s f...

Страница 21: ...acompression Transcoder described above there is a single slot MPEG 4 AVC Ultracompression Transcoder which fits in a single PMC slot The advantages for a single slot transcoder are Fits in a single s...

Страница 22: ...iPlex control station Configuration Using the Front Panel Controls 1 Apply power 2 Reconfigure the unit You can change the unit s IP address IP mask IP gateway root password date time and boot source...

Страница 23: ...fication Guide 23 CLI serial port telnet or SSH secure Refer to the Command Line Interface Reference Guide for detailed information SNMP v2 or v3 secure Refer to the Network Management Monitoring Refe...

Страница 24: ...24 iPlex Installation and Hardware Specification Guide...

Страница 25: ...25 Hardware Specification and Installation Chapter 2...

Страница 26: ...95 Non condensing Operating Altitude to 13 123 ft 4000 meters Power Rating and Specifications Input Power Requirements AC 100 240 V 47 63 Hz 3 6 Amps max DC 48 V 10 Amps max Power Outlet Installation...

Страница 27: ...er if the site installation is not ready Do not discard the shipping container and shipping materials These items will be needed if there is a warranty return or if the chassis needs to be moved or sh...

Страница 28: ...nt Instructions The following instructions will guide you through installing your iPlex chassis into a typical rack mount cabinet or chassis Rack mount Check List The iPlex chassis rack mount kit incl...

Страница 29: ...attached position the chassis in place with the proper rack mount hole pattern Step 3 Attach the chassis securely using 12 24 x or other rack specific rack mount screws To attach the front mount chass...

Страница 30: ...a second person installs the rack mounting screws To prevent injury keep your back straight and lift with your legs not your back WARNING To prevent personal injury when mounting or servicing the uni...

Страница 31: ...ake and air exhaust on the sides and a cabinet wall or other barrier You should also calculate the heat load from other heat generating devices and determine if an off set is required between units to...

Страница 32: ...connector to the scraped hole on the rack rail according to local practice as shown in Figure that follows Power The iPlex has a maximum power dissipation of 300 Watts The total power required per sy...

Страница 33: ...nnected at the source 4 Prepare two power wires rated at a minimum of 10 Amps 48 VDC and return 5 Use a 1 4 inch flathead screwdriver to loosen the panhead screws from the and terminal connections 6 U...

Страница 34: ...minal block and across the power cabling should be zero 9 Label the power wires with and 10 Route the power cables under the chassis and lace according to local practice Verify the power supply is off...

Страница 35: ...een when the link is established flickering green when there is network activity off when no link is established ETH2 Link Activity Green when the link is established flickering green when there is ne...

Страница 36: ...hernet SFP 2 Port Serial Interface Control Console Port Alarm Port Carrier Card 1 Slot Carrier Card 2 Slot AC iPlex DC iPlex Fans The iPlex chassis contains integrated fan module The operation of the...

Страница 37: ...arm Port Connector The following scheme shows the cable fitting for the alarm port Pin No Connection 1 TANDBERG Television debug use leave open 2 3 Critical Alarm output normally open 4 Critical Alarm...

Страница 38: ...BNC and activity LEDs ASIIn Submodule The ASIIn submodule is distinguished by its label ASI IN and by a white line around the BNC connectors Looking at the interface view of the card you can see BNC...

Страница 39: ...tors and activity LEDs Specifications Mechanical Height 0 509 inches Width 2 913 inches Depth 5 866 inches Connectors BNC Indicators RDY Ready Green LED ACT Active Green LED State RDY ACT Power Off Of...

Страница 40: ...urces For an analog video signal you can configure the encoder input as S Video or composite video Alternately the encoder can receive digital video input through the Serial Digital Interface SDI The...

Страница 41: ...osite Video In V1 or SDI Specifications Mechanical Height 0 509 inches Width 2 913 inches Depth 5 866 inches Connectors 37 Pin Micro D Connector BNC TIP The Advanced Encoder can be distinguished from...

Страница 42: ...f extract ing embedded audio from the SDI input The MPEG 4 AVC Encoder s components seen from the front are as follows Audio Connector S Video In chrominance C or Composite Video In V2 activity LEDs r...

Страница 43: ...pt SD signals The interface options are Composite S Video and SD SDI in the exact same arrangement as the MPEG 2 Encoder Plus and the H 264 Advanced Encoder The encoder supports up to six audio stereo...

Страница 44: ...for uncompressed digital video input with support for both HD SDI and SD SDI as well as the audio interface see the illustration The upper part of the front view is a blank face panel Specifications...

Страница 45: ...The SD interface option also includes the audio interface which is identical to that of the HD interface State RDY ACT Power Off or Not Initialized Off Off MPEG Encoder enabled no video present on se...

Страница 46: ...th 5 865 inches Depth 6 015 inches Connectors 37 Pin Micro D Connector BNC Indicators RDY Ready Green LED ACT Active Green LED State RDY ACT Power Off or Not Initialized Off Off MPEG Encoder enabled n...

Страница 47: ...ual slot encoder Up to 8 audio channels can be encoded by each card HD Single slot Encoder The Single slot HD encoder provides one BNC for uncompressed digital video input with support for both HD SDI...

Страница 48: ...The SD encoder also includes the audio interface which is identical to that of the HD encoder Specifications Mechanical Height 0 509 inches Width 2 913 inches Depth 6 015 inches Connectors 37 Pin Mic...

Страница 49: ...front are as follows LINE activity LED and STATUS activity LED receive and transmit SC duplex connector Single mode Multi mode S T A T U S SM L I N K OC 3 STM 1 ATM S T A T U S MM L I N K OC 3 STM 1...

Страница 50: ...s essentially the same as the other ATM cards ATM DS3 ATM Asynchronous Transfer Mode A network technology for both local and wide area networks LANs and WANs that supports real time voice and video as...

Страница 51: ...TUS Active Green LED LINK ATM E3 STATUS IN OUT LINK STATUS IN OUT ATM DS3 BNC Connectors for audio video or networking Activity LEDs State Link Status Power Off or Not Initialized Off Off Receiving si...

Страница 52: ...s work cooperatively and provide ONE channel of transcoding or one transcoder input and one transcoder output ports When configured to do transrating they can provide multiple transrator input and out...

Страница 53: ...tes compared to MPEG 2 The transcoder also provides full live video compression up to HD The MPEG 4 AVC Ultracompression Transcoder accepts both SD and HD Video Format inputs It provides six Audio cha...

Страница 54: ...s are also dynamically generated for any audio channels that are replicated and transcoded The transcoder has a scan conversion capability which controls the picture resiz ing An MPEG 4 AVC Ultracompr...

Страница 55: ...are Fits in a single slot so 8 of them can be fitted in one iPlex chassis Improved video quality compared to the dual slot encoder Up to 8 audio channels can be encoded by each card An AVC Ultracompre...

Страница 56: ...tions to the network There are two types of SFP optical transceivers available one for MMF cable and one for SMF cable Both use an LC connector to provide 1000BASE T full duplex connectivity between m...

Страница 57: ...onnector ASI Output Cables Coaxial cable RG 6 U 75 ohm with BNC male connector ATM Cables Single mode fiber cable 8 5 125 m duplex with SC connector Multi mode fiber cable 62 5 125 m duplex with SC co...

Страница 58: ...Specification Guide Unshielded twisted pair CAT 5e or CAT 6 cable with RJ 45 connector 10 100 Ethernet Cables Unshielded twisted pair CAT 5 cable with RJ 45 connector Console Cables Serial null modem...

Страница 59: ...NTI STATIC CAUTION A TANDBERG Television part is packaged in an anti static bag for protection Keep the part in its anti static bag until you are ready for installation You must be static free to inst...

Страница 60: ...so that the components are face up Use the following procedure to install a submodule into the carrier card To install a submodule into the MCM blade 1 Carefully remove the submodule from its anti st...

Страница 61: ...he back toward you insert the front plate through the slot and carefully align the dual mating connectors on the carrier card 3 Align the standoff posts with the matching holes on the carrier card and...

Страница 62: ...To remove a blank plate you just push it out from the inside Installing a Carrier Card The carrier card is installed in either slot 1 or slot 2 of the iPlex chassis The fol lowing steps are required t...

Страница 63: ...of the left and right card guides 2 With the edges of the carrier card aligned with the card guides slide the carrier card along the card guides CONTROL REDUNDANCY CONSOLE ALARM GE1 GE2 100 240 VAC 6...

Страница 64: ...located on the chassis card cage 5 Screw the captive fasteners into the locked position 4 3 2 1 CONTROL REDUNDANCY CONSOLE ALARM GE1 GE2 100 240 VAC 6A A U D I O MPEG 2 ENC CI Y SDI C2 C RDY ACT A U...

Страница 65: ...before pulling out the blade Installing a Blank Face Plate If you have one carrier card and an open carrier card slot on your iPlex chassis you must fill the open slot with a blank face plate To insta...

Страница 66: ...may be faulty In either case contact TANDBERG Television Customer Support Encoders If the RDY LED never illuminates the encoder may be faulty or the iPlex has not initialized it correctly Contact TAND...

Страница 67: ...e module edge connector in the down position 2 Slide the SFP module until it engages with the SFP connector on the iPlex 3 Close the bail lock to retain the SFP properly 4 The module is ready to be co...

Страница 68: ...place any dust caps and store properly Replacing the Backup Battery The battery on the iPlex system board powers a Real Time Clock RTC for up to 10 years in the absence of power When the battery start...

Страница 69: ...arge precautions 2 Remove the cover from the iPlex WARNING Battery replacement should be performed by a Customer Service trained technician WARNING Danger of explosion if battery is incorrectly replac...

Страница 70: ...from its socket 5 Dispose of the battery according to local ordinances 4 3 2 1 4 3 2 1 CONTROL REDUNDANCY CONSOLE ALARM GE1 GE2 100 240 VAC 6A A U D I O MPEG 2 ENC CI Y SDI C2 C RDY ACT A U D I O MPE...

Страница 71: ...iPlex Installation and Hardware Specification Guide 71 6 Remove the new battery from its package and observe the correct polarity insert it in the battery socket 7 Replace the cover on the chassis...

Страница 72: ...72 iPlex Installation and Hardware Specification Guide...

Страница 73: ...73 Control Station Setup Chapter 3...

Страница 74: ...te management PC with Web browser if not using the front panel of the iPlex to reconfigure the unit Cables required to connect to your network configuration Management PC The Management PC if used mus...

Страница 75: ...me or IP address is changed through web interface If there is an important system message this message is displayed instead The first and last columns of both lines are filled with character to note t...

Страница 76: ...cked a limited menu is displayed You have to unlock the front panel first to access the normal main menu You can see the cur rent configuration only until the front panel is unlocked Submenu Choices M...

Страница 77: ...of IP config IP address and the netmask is configured in the same menu because they have to be validated together Submenu of TFTP config Submenu of Syslog config Submenu of System config 2 D a t e a...

Страница 78: ...The following is the example of string field It works as overwrite mode You can change the character on the cursor Only the last character in the string can be deleted by selecting the space character...

Страница 79: ...pet that the ranges of each number field are different IP Address Field The IP address field consists of four number fields You edit on a character basis and the cursor skips the separators Root Passw...

Страница 80: ...o the iPlex through the serial port Turn on the main power switch on the iPlex chassis and by using 9800 Baud HyperTerminal for Windows or equivalent and specifying the appropriate parameters the init...

Страница 81: ...press CR Re Enter the ROOT password MIN 6 MAX 12 Type your password again and press CR The initial screen will appear again Choose an option Type one of the following 5 6 7 or 8 and press CR or leave...

Страница 82: ...yping 0 CR You will see the following message Press break sequence X W CR in 10 seconds to stop autoboot Again if you want to interrupt this command you must type Ctrl X Ctrl W CR When the iPlex boots...

Страница 83: ...Management Console MPMC CLI If an Ethernet or a Web GUI connection is not available you can configure the Tandberg iPlex with the Command Line Interface CLI using the management PC TIP It is recommen...

Страница 84: ...me and password and click the Login button The iPlex allows you to change these default passwords and or create new login ID and passwords into the sys tem from the Maintenance Administration page Men...

Страница 85: ...s will display You can achieve the same thing through the menu tree In the ASI Statistics page by default you will see MPEG Programs information on the Transport Stream By clicking Elements or Streams...

Страница 86: ...you verify that the iPlex is receiving a Transport Stream you need to create an output stream for routing purposes through either a UDP Out or an ASI Out port If you have an ASI Out submodule you onl...

Страница 87: ...k box to remove entries After completing the configuration click the Apply button Configuring an ASIOut If you have an ASIOut submodule then you can route programs through it Click the ASIOut port fro...

Страница 88: ...88 iPlex Installation and Hardware Specification Guide...

Страница 89: ...89 Connecting iPlex to the Internet Firewall Issues Appendix A...

Страница 90: ...and read these passwords Since the first method is known not to happen the focus will be on the second method Access to the iPlex through the CLI and Web interfaces share the same usernames and passw...

Страница 91: ...error free It is recommended that the iPlex be protected by a firewall The remainder of this chapter explores practical options for deploying a firewall Firewall Options This section discusses options...

Страница 92: ...Control PC The NAT Firewall is configured to forward access to the appropriate port TCP port 5900 in case of VNC from the outside to the control PC Optional but highly recommended the firewall should...

Страница 93: ...wed IP addresses In that case a possible DoS attack would be to generate packets with spoofed IP addresses and flood the iPlex The firewall in this case has no way of distinguishing such packets from...

Страница 94: ...on Conclusion Even though TANDBERG Television has taken every precaution in the iPlex software to protect it against intrusion and other forms of attack it is not possible to guarantee that the iPlex...

Страница 95: ...tatic 59 battery disposal 69 grounding 60 65 66 handling and lifting procedures 30 installation 59 warranty and non Tandberg parts 59 chassis 16 AC power outlet requirements 26 basic components 35 hom...

Страница 96: ...speeds 17 installing a submodule 60 submodules 18 mechanical specifications 26 menus configuration 85 navigation 85 statistics 85 MPEG 4 AVC Ultracompression Single slot Transcoder 55 MPEG 4 AVC Ultr...

Страница 97: ...d access 90 serial null modem cable 58 statistics 85 submodule installation 60 blank plates 62 T tech support contact info 15 tech support pre call checklist 15 TRM DSP video processing submodules 20...

Страница 98: ...Beta Beta iPlex Installation and Hardware Specifications Guide 98...

Отзывы: