Table 7-14: Fault Criteria for Setting TSNCP SD Flags
Fault Type
Protection
Class
Enable/
Disable
Application Notes
HO Path Signal Degrade
(HP-DEG)
SNC/N
YES
only HO VC layer SNCP
HO Path Unacceptable Short-term Errors
(HP-DEG)
SNC/N
YES
only HO VC layer SNCP
LO Path Signal Degrade
(LP-DEG)
SNC/N
YES
only LO VC layer SNCP
LO Path Unacceptable Short-term Errors
(LP-DEG)
SNC/N
YES
only LO VC layer SNCP
HO TC Signal Degrade
(HTC-DEG)
SNC/S
YES
only HO Tandem VC
layer TSNCP
HO TC Unacceptable Short-term Errors
(HTC-DEG)
SNC/S
YES
only HO Tandem VC
layer TSNCP
LO TC Signal Degrade
(LTC-DEG)
SNC/S
YES
only LO Tandem VC
layer TSNCP
LO TC Unacceptable Short-term Errors
(LTC-DEG)
SNC/S
YES
only LO Tandem VC
layer TSNCP
7.6.3.2
Locally Entered Operator Switching Requests
These Forced Switch, Manual Switch, Clear requests are as described for VC-trail
SNCP in Section 7.5.3.2 above.
7.6.3.3
Remote Multiplexer Switching Requests (Bi-directional Switching Mode)
The TSNCP protection switch controller responds to remote requests from the SMA at
the far end of the protected tandem VC-trail, when operating in bi-directional mode.
Each protection switch controller generates these requests from its own locally
detected failures, conditions, and operator entered switch requests. It transmits them
over the (network) APS channels to the far end. The request types are listed below:
1
Forced Switch (Worker Channel).
2
Forced Switch (Protection Channel).
3
Manual Switch (Worker Channel).
4
Manual Switch (Protection Channel).
The above remote requests are derived from operator entered requests. They
carry the same weighting as locally entered operator requests.
5
Signal Fail (Worker Channel).
6
Signal Degrade (Worker Channel).
7
Signal Fail (Protection Channel).
8
Signal Degrade (Protection Channel).