Marconi OMS 1200
Technical Product Description
221 02-ZAP 701 25/1 Rev C 2006-08-04
© Ericsson AB 2006
03PHB00004AAV-CUA
Commercial in confidence
69 (136)
Table 7-7: Slot Equipping rules for Vertically Extended 63x2M Unbalanced LTU -
03HAM 00009 AAL
2M LTU 1
2M LTU 2
2M LTU 3
2M LTU 4
S3_
01
S3_
02
S3_
03
S3_
05
S3_
06
S3_
07
S3_
09
S3_
10
S3_
11
S3_
13
S3_
14
S3_
15
OMS 1260 63x2M
LTU – 2M Tributary
1
OMS 1260 63x2M
LTU – 2M Tributary
2
OMS 1260 63x2M
LTU – 2M Tributary
3
OMS 1260 63x2M
LTU – 2M Tributary
4
Note:
The Vertically Extended LTU increases the subrack height by 180mm.
Protection Scheme Summary
In summary, the OMS 1200 includes the following protection schemes in line with
generic SMA products:
•
Network Level Protection Schemes:
−
SDH Trail - Linear Multiplex Section Protection (Linear MSP)
−
VC-trail - Sub-Network Connection Protection (SNCP)
−
PDH Trail - PDH Tributary Port Protection.
−
Two Fibre MS-SPRING is available for OME1240 and OMS 1260 fitted
with STM-4/16 Core cards.
•
SMA Equipment Level Protection Schemes:
−
SDH/PDH/ETA Tributary Interface Card Protection
−
Core Card Protection.
Network level protection schemes protect against failure of equipment and line plant
external to the SMA (for example SNC protection). These schemes are intended to
provide enhanced availability for complete end-to-end traffic trails, or segments of
them, in a network. Given worker and protection channel traffic from the network, the
SMA uses SDH section and path layer monitoring to determine which is the most
viable transport channel and switches accordingly.
Equipment level protection schemes increase the availability of traffic paths within the
SMA equipment by providing fast, autonomous recovery from card/unit failures. The
peripheral traffic interface cards internally monitor the quality of signals received from
each core unit. On detection of faults, they switch accordingly.