Marconi OMS 1200
Technical Product Description
221 02-ZAP 701 25/1 Rev C 2006-08-04
© Ericsson AB 2006
03PHB00004AAV-CUA
Commercial in confidence
105
(136)
3
Mode Mismatch.
Raised if a mismatch of the local and remote SMA operating modes is
detected as shown in Table 7-18.
Table 7-15: TSNCP Mode Mismatch
Local Remote
Bidirectional revertive
Bidirectional non-revertive
Bidirectional non-revertive
Bidirectional revertive
The criteria for this failure is based on that specified for STM-n Linear MSP
schemes, but with the following exceptions:
•
The three failure conditions are logically ORed to provide a single
alarm indication, TSNCP APS Protocol Fail. It identifies that either the
APS protocol data is corrupted, or bi-directional ganged switching is
not occurring at the two SMAs involved, or the TSNCP operating
modes are not identically configured at each of the two SMAs.
7.6.5
Protection State Reports
The following lists identify the various states of the TSNCP protection switch
controller, and which are reported.
1
TSNCP States - Locally Initiated Only.
•
No Request - Traffic on Worker
•
No Request - Traffic on Protection
•
Remote Request to Worker - Traffic on Worker
•
Remote Request to Protection - Traffic on Protection
•
Do not Revert - Traffic on Protection
•
Wait to Restore - Traffic on Protection
•
Manual Switch to Protection - Traffic on Protection
•
Manual switch to Worker - Traffic on Worker
•
Signal Degrade on Worker - Traffic on Protection
•
Signal Degrade on Protection - Traffic on Worker
•
Signal Fail on Worker - Traffic on Protection.
•
Forced Switch to Protection - Traffic on Protection
•
Signal to Worker - Traffic on Worker.