background image

LBI-39055

7

• 

Audio Tower-to-Supervisor Headset Jack Box
(if used)

• 

Audio Tower-to-Operator Headset Jack Box
(if used)

• 

Audio Tower-to-Boom/Gooseneck Mic (if used)

• 

Audio Tower-to-Boom/Gooseneck PTT and
Monitor Switches (if used)

• 

Audio Tower-to-Footswitches (if used)

• 

Audio Tower-to-Volume Controller Box (if used)

• 

Audio Tower-to-Speakers (if used)

• 

PC, Video Display Monitor and Audio Tower AC
Power Connections

In addition, the following interconnections are required

for optional equipment, if employed:

• 

Audio Tower-to-Recorder Equipment

• 

Audio Tower-to-Pager

• 

Audio Tower-to-External Equipment Controlled
by Relay Form-A Contacts

• 

Audio Tower-to-Call Director

IMPORTANT NOTE

Unless otherwise noted, all procedures in this
manual should be performed in the order
presented.

CEC/IMC INTERCONNECTIONS

The C3 Maestro console interfaces to the CEC/IMC via

a full-duplex serial control data link and a 4-wire audio
connection. In addition, each unselect speaker requires an
additional 2-wire connection from the CEC/IMC. Also, if
the console is interfaced to a Call Director for Call Director
telephone patch operations, an additional 4-wire audio link
between the C3 Maestro and the CEC/IMC is required. See
Figures 1 and  8. As shown in Figure  8, all CEC/IMC
interconnections are made at Concentrator Cards. These
cards are located at the back of the CEC/IMC cabinet.

CEC/IMC Concentrator Card pin-out details are listed

on the customer-specific system documentation print-outs.
These print-outs are included with the CEC/IMC when it
ships from the factory. See the CEC/IMC Digital Audio
Switch Customer-Specific System Documentation

maintenance manual, LBI-38939 for sample print-outs and
complete print-out explanations.

Control Data Link

Either an RS-422 (four-wire) or an RS-232 (three-

wire) serial control data link may  be employed. RS-422
control data interfacing is recommended and  in most all
installations, it is used for co-located console
interconnections. RS-232 has poorer noise performance
than RS-422 and therefore, it should never be used for
cable runs more than 50 feet in length.

If required for a remote console installation, full-

duplex 4-wire data modems can  be used between the  C3
Maestro and  the CEC/IMC. See the following subsection
for additional remote console wiring and modem
configuration details.

At the C3 Maestro, control data connections terminate

at the PC's COM1 serial port. On the CEC/IMC side, the
console's control data connections are made at a Data
Concentrator Card. As shown in Figure 8A, punch blocks
may be installed between the  CEC/IMC and  the console.
Also shown in the  figure, a Concentrator Card Cable
interconnects the Data Concentrator Card to the CIM
Controller Board via the CEC/IMC Backplane.

All Data General (DG) Dasher computers are factory

equipped with a built-in COM1 serial port on the main
board that can be wired for RS-422 or RS-232 operation.
The connector is a DB-25 type. See Figure 8A.

Computers not equipped with a main board RS-422

capable COM1 port normally have a plug-in RS-422 board
installed in an expansion slot. This board has  a DB-25
connector at its rear plate. Approved RS-422 plug-in board
model numbers include RS422AT-P,  RS422I-P and
3PXOCC1A. An RS422x-x board (part number
344A3927P38) can easily be identified by the  presence of
two LED  indicators visible on its rear plate. If a plug-in
RS-422 board is used, the  PC's main board COM1 port
must be disabled. This is done via a DIP switch, jumper, or
a BIOS set-up program. For COM1 port enable/disable
configuration details, refer to the section entitled
"SOFTWARE INSTALLATION AND SET-UP
PROCEDURE
", subsection "PC CMOS SET-UP
PROGRAM
" later in this manual, and the PC
manufacturer's documentation.

Factory-installed RS422x-x (344A3927P38) or

3PXOCC1A plug-in boards are configured correctly before
the PC ships from the factory. This configuration includes
disabling the PC's main board COM1 port per
manufacturer's instructions.

Содержание C3 MAESTRO LBI-39055

Страница 1: ...c Audio ALC Enable Disable DIP Switch 6 I O Board 6 INTERCONNECTING THE EQUIPMENT 6 CEC IMC INTERCONNECTIONS 7 Control Data Link 7 Remote Console Interconnections Via A 4 Wire Modem 8 Audio Links 9 PE...

Страница 2: ...TION 21 Console User Profile Configuration 21 System Manager Database Uploads 21 Console Privilege Lists 22 Saving Database Information 22 SYSTEM TESTS 22 LOW LEVEL TESTS 22 Recommended Test Equipment...

Страница 3: ...ibed NOTE C3 Maestro application software version 3 0x requires C3 Maestro Logic Board firmware version 3 02 or later CEC IMC Controller and Audio Board firmware version 3 0x or later and CEC IMC Mana...

Страница 4: ...sole system BOARD SET UP IMPORTANT NOTE Unless otherwise noted all procedures in this manual should be performed in the order presented LOGIC BOARD Normally the Logic Board is configured correctly and...

Страница 5: ...stro console system ships from the factory If the console system is ordered with multiple unselect speakers 2 or 3 or with the Call Director patch option two Audio PA Boards are installed DIP switches...

Страница 6: ...h SW1 on the Audio Matrix Board is used to independently enable or disable each microphone s automatic level control ALC circuit The switch has four 4 positions one for each mic that may be connected...

Страница 7: ...d in most all installations it is used for co located console interconnections RS 232 has poorer noise performance than RS 422 and therefore it should never be used for cable runs more than 50 feet in...

Страница 8: ...g 3002 data grade specifications must be employed between the CEC IMC and the C3 Maestro in a remote console installation Figure 8B shows typical control data interconnections for a remote console ins...

Страница 9: ...recommended TABLE 5 CONSOLE TO CEC IMC BALANCED LINE AUDIO INTERCONNECTIONS STANDARD 6 POSITION 4 CONTACT RJ 11 PIN NUMBER AUDIO PA BOARD 6 POSITION 4 CONTACT RJ 11 PIN NUMBER TO FROM CEC IMC 1 none n...

Страница 10: ...LBI 39055 10 Figure 8A CEC IMC To C3 Maestro Interconnections Co Located...

Страница 11: ...LBI 39055 11 Figure 8B CEC IMC To C3 Maestro Interconnections Remote And Or RS 232...

Страница 12: ...ole s application program Connect the standard PC keyboard to the PC in accordance with the manufacturer s instructions Video Display Monitor Interconnect the video display monitor s video cable to th...

Страница 13: ...gooseneck microphone option CRMC3F or equivalent may be connected to the Audio Tower Mount the microphone in accordance with the instructions supplied With the gooseneck microphone the supplied male D...

Страница 14: ...ector to the respective female DB 9 connector on the I O Board Volume Controller Box if used If the console system is equipped with speakers the Volume Controller Box must be used Typically it is loca...

Страница 15: ...in LBI 39062 for audio signal output level specifications Figure 10 I O Board Recorder Terminal Block Pin Out Pager Input if used Pager connections are also located on a terminal block on the I O Boar...

Страница 16: ...e considered LINE C and LINE D respectively Figure 7 shows modular jack locations LINE C if used for a second unselect speaker connects to CEC IMC CIM channel line 3 Call Director LINE D connects to C...

Страница 17: ...into the CD This handset overrides all audio connections to the Audio Tower The operator talks directly to the phone via the handset instead of using the console s headset or mic speaker Dry contact...

Страница 18: ...C CMOS SET UP PROGRAM C3 Maestro software is factory installed on the PC s hard disk drive and the software is configured properly for standard installations Therefore during a typical console configu...

Страница 19: ...BLE 12 C3 MAESTRO PC FILE DIRECTORIES AND FILES ROOT DIRECTORY C CONSOLE DIRECTORY C CONSOLE UTILITY DIRECTORY C UTIL AUTOEXEC BAT CONFIG SYS COMMAND COM IO SYS MSDOS SYS AUXIO DAT CONFIG DAT CONKEY C...

Страница 20: ...number that is only used for Call Director telephone patch operations The default value for this ID is zero 0 no Call Director Valid Call Director ID range is 1 16382 The zero setting should not be c...

Страница 21: ...ser Profile configuration to the console 7 When the User Profile Successfully Written message is displayed return to the CEC IMC Manager main menu If an Unable to Write User Profile message appears or...

Страница 22: ...ity to control the Audio Tower s audio matrix circuitry It also verifies the line coupling circuitry and the speaker amplifier circuitry Cross point audio matrix switches are controlled opened and clo...

Страница 23: ...Speaker B If not send the LINE B input to the SPKR B output by typing the following command F2 6641 Enter Adjust the unselect speaker Speaker B volume knob up and down and verify the volume changes T...

Страница 24: ...nd the CEC IMC The procedures assume all equipment has been interconnected and set up in accordance with the previous instructions presented in this manual Control Data Link The C3 Maestro console and...

Отзывы: